Rockwell-automation 150 USE MN/SMC DIALOG + CONTROLLER Manual de usuario Pagina 109

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 189
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 108
Options
7-25
Figure 7.21 Slow Speed with Braking Option Sequence of Operation
Start Brake
Motor
Speed
100%
Push Buttons
Start
Stop
Slow Speed
Auxiliary
Contacts
Normal
Up-to-speed
Open
Open
Open
Closed
Closed
Closed
Braking
Run Slow
Speed
Time (seconds)
!
ATTENTION: The user is responsible for
determining which stopping mode is best suited to the
application and will meet applicable standards for
operator safety on a particular machine.
Vista de pagina 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 188 189

Comentarios a estos manuales

Sin comentarios