Installation Instructions
POINT I/O Module with 8 Configurable
24V DC Points and DeviceLogix
Catalog Numbers 1734-8CFGDLX
Topic Page
Important User Information 2
Environment and Enclosure 3
Prevent Electrostatic Discharge 4
About the Module 4
Before You Begin 5
Install the Mounting Base 6
Install the Module 7
Install the Removable Terminal Block 9
Wire the Module 11
Wiring Diagram 12
Configure the Module 13
Interpret the Indicators 20
Specifications 23
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - 24V DC Points and DeviceLogix

Installation InstructionsPOINT I/O Module with 8 Configurable 24V DC Points and DeviceLogixCatalog Numbers 1734-8CFGDLX Topic PageImportant User Inf

Pagina 2 - Important User Information

10 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Install a 1734-TOPS Base1. Position

Pagina 3 - Environment and Enclosure

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 11Publication 1734-IN039A-EN-P - March 2009Wire the ModuleSee the figure and tab

Pagina 4 - About the Module

12 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Wiring DiagramChannel Terminal Numbe

Pagina 5 - Before You Begin

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 13Publication 1734-IN039A-EN-P - March 2009Configure the ModuleRead this section

Pagina 6 - Install the Mounting Base

14 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009You can select other produced assemb

Pagina 7 - Install the Module

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 15Publication 1734-IN039A-EN-P - March 2009Default Data Map - Consumed Assembly

Pagina 8 - 1734-TOP Base

16 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009You can select other consumed assemb

Pagina 9 - Remove a Mounting Base

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 17Publication 1734-IN039A-EN-P - March 2009Data [14] Masterless Produce PIT (ms)

Pagina 10 - Remove a 1734-TOPS Base

18 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Data [38] Peer 5 - EPR (ms)Data [39]

Pagina 11 - Wire the Module

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 19Publication 1734-IN039A-EN-P - March 2009Configuration of the 1734-8CFGDLX mod

Pagina 12 - Wiring Diagram

2 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Important User InformationSolid state

Pagina 13 - Configure the Module

20 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Interpret the IndicatorsSee the figu

Pagina 14

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 21Publication 1734-IN039A-EN-P - March 2009Network StatusStatus Description Reco

Pagina 15 - Publication

22 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009DeviceLogix StatusI/O StatusStatus D

Pagina 16

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 23Publication 1734-IN039A-EN-P - March 2009Specifications S

Pagina 17

24 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009General Specifications Attribute Val

Pagina 18

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 25Publication 1734-IN039A-EN-P - March 2009Environmental Specifications Attribut

Pagina 19 - RSNetWorx for DeviceNet

26 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009EFT/B immunity IEC 61000-4-4: ±3 kV

Pagina 20 - Interpret the Indicators

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 27Publication 1734-IN039A-EN-P - March 2009CertificationsCertification (when pro

Pagina 21 - Network Status

Publication 1734-IN039A-EN-P - March 2009 PN 41923Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwell Automa

Pagina 22 - I/O Status

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 3Publication 1734-IN039A-EN-P - March 2009Environment and EnclosureATTENTIONThis

Pagina 23

4 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Prevent Electrostatic Discharge Ab

Pagina 24 - General Specifications

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 5Publication 1734-IN039A-EN-P - March 2009Before You BeginSee the figures to fam

Pagina 25 - Environmental Specifications

6 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 2009Install the Mounting BaseFollow these

Pagina 26

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 7Publication 1734-IN039A-EN-P - March 2009Install the ModuleThe module can be in

Pagina 27 - Certifications

8 POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix Publication 1734-IN039A-EN-P - March 20091734-TOP BaseFollow these steps to in

Pagina 28 - Installation Assistance

POINT I/O Module with 8 Configurable 24V DC Points and DeviceLogix 9Publication 1734-IN039A-EN-P - March 2009Install the Removable Terminal BlockRe