Installation Instructions
ControlLogix DeviceNet Scanner Module
Catalog Numbers 1756-DNB, Series C and D
Topic Page
Important User Information 2
Preventing Electrostatic Discharge 3
European Hazardous Location Approval - European Zone 2 Certification 4
Environment and Enclosure 5
North American Hazardous Location Approval 6
About this Publication 6
About the Module 7
Before You Begin 7
Determine Module Slot Location 8
Change Module Settings 9
Install the Module in the Chassis 16
Configure the Scan List 27
Monitor and Troubleshoot Devices in the Module Scan List 27
Interpret the Status Indicators 35
Understand ControlLogix Controller Interface Structures 38
Specifications 43
Additional Resources 47
Vista de pagina 0
1 2 3 4 5 6 ... 47 48

Indice de contenidos

Pagina 1 - Installation Instructions

Installation InstructionsControlLogix DeviceNet Scanner ModuleCatalog Numbers 1756-DNB, Series C and DTopic PageImportant User Information 2Preventing

Pagina 2 - Important User Information

10 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Set the Communication RateThe 1756-DNB scanner module supports the

Pagina 3

ControlLogix DeviceNet Scanner Module 11Publication 1756-IN566D-EN-P - June 2008 Communication Rate Rotary SwitchSwitch Settings and Communication

Pagina 4 - Certification

12 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Set the Rotary SwitchUse the communication (data) rate rotary swit

Pagina 5 - Environment and Enclosure

ControlLogix DeviceNet Scanner Module 13Publication 1756-IN566D-EN-P - June 20085. In the Data Rate field, select the communication (data) rate.6.

Pagina 6 - About this Publication

14 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Set the Rotary SwitchesUse the node address rotary switches to cha

Pagina 7 - Before You Begin

ControlLogix DeviceNet Scanner Module 15Publication 1756-IN566D-EN-P - June 2008Restore the Factory Default SettingsThe out-of-box reset will clea

Pagina 8

16 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Install the Module in the ChassisWARNINGWhen you insert or remove

Pagina 9 - Change Module Settings

ControlLogix DeviceNet Scanner Module 17Publication 1756-IN566D-EN-P - June 2008Wire the DeviceNet ConnectorUse an open-style 5- or 10-position li

Pagina 10 - Set the Communication Rate

18 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Connect the Module to the DeviceNet NetworkAttach the connector to

Pagina 11 - Publication

ControlLogix DeviceNet Scanner Module 19Publication 1756-IN566D-EN-P - June 2008Connect to the Module Via the USB PortThe module has a USB device

Pagina 12 - Set the Rotary Switch

2 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Important User InformationSolid state equipment has operational cha

Pagina 13 - Switch Settings

20 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Set Up the USB DriverTo connect your 1756-DNB scanner module via a

Pagina 14 - Set the Rotary Switches

ControlLogix DeviceNet Scanner Module 21Publication 1756-IN566D-EN-P - June 2008These dialogs appear consecutively.4. Click Finish to set up your

Pagina 15 - IMPORTANT

22 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 20085. In RSLinx software, from the Communications pull-down menu, cho

Pagina 16

ControlLogix DeviceNet Scanner Module 23Publication 1756-IN566D-EN-P - June 2008Apply Chassis PowerIMPORTANTDo not simultaneously flash upgrade th

Pagina 17 - Wire the DeviceNet Connector

24 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Check Power Supply and Module StatusCheck the status indicators an

Pagina 18

ControlLogix DeviceNet Scanner Module 25Publication 1756-IN566D-EN-P - June 2008Install or Remove the Module Under PowerYou can install or remove

Pagina 19 - DeviceNet Port

26 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Remove or Replace the ModuleIMPORTANTIf you want to replace an exi

Pagina 20 - Set Up the USB Driver

ControlLogix DeviceNet Scanner Module 27Publication 1756-IN566D-EN-P - June 2008Configure the Scan ListUse RSNetWorx for DeviceNet software to con

Pagina 21

28 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Alphanumeric Status Messages The following table summarizes the st

Pagina 22 - 1756-IN566D-EN-P - June 2008

ControlLogix DeviceNet Scanner Module 29Publication 1756-IN566D-EN-P - June 2008DeviceNet Status CodesThe following table summarizes the codes.Dev

Pagina 23 - Apply Chassis Power

ControlLogix DeviceNet Scanner Module 3Publication 1756-IN566D-EN-P - June 2008Preventing Electrostatic DischargeATTENTIONThis equipment is sensit

Pagina 24 - MOD/NET I/O OK

30 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 200874 Scanner detected data overrun on DeviceNet communication port.•

Pagina 25

ControlLogix DeviceNet Scanner Module 31Publication 1756-IN566D-EN-P - June 200878 Device is configured in scan list, but not communicating. It ha

Pagina 26 - Remove or Replace the Module

32 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 200882 Error detected in sequence of fragmented I/O messages from devi

Pagina 27 - Configure the Scan List

ControlLogix DeviceNet Scanner Module 33Publication 1756-IN566D-EN-P - June 200885 During runtime, the data size sent by the slave device does not

Pagina 28 - Alphanumeric Status Messages

34 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 200891 Bus-off condition likely due to cable or signal errors.• Cycle

Pagina 29 - DeviceNet Status Codes

ControlLogix DeviceNet Scanner Module 35Publication 1756-IN566D-EN-P - June 2008Interpret the Status IndicatorsThe status indicators on the module

Pagina 30

36 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008 Indicator State and DescriptionIndicator State DescriptionModule/

Pagina 31

ControlLogix DeviceNet Scanner Module 37Publication 1756-IN566D-EN-P - June 2008Indicator State DescriptionModule/ Network (MOD/NET)Flashing red(1

Pagina 32

38 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Understand ControlLogix Controller Interface StructuresThe 1756-DN

Pagina 33

ControlLogix DeviceNet Scanner Module 39Publication 1756-IN566D-EN-P - June 2008Module Command Register Bit DefinitionsThe bits of the Module Comm

Pagina 34

4 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008European Hazardous Location Approval - European Zone 2 Certificatio

Pagina 35

40 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008Input StructureThe controller receives input I/O by reading input

Pagina 36

ControlLogix DeviceNet Scanner Module 41Publication 1756-IN566D-EN-P - June 2008Module Status Register Bit DefinitionsThe Module Status Register b

Pagina 37

42 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008The status structure consists of these data elements.Status Struct

Pagina 38 - Output Structure

ControlLogix DeviceNet Scanner Module 43Publication 1756-IN566D-EN-P - June 2008SpecificationsControlLogix DeviceNet Scanner Module, Cat. No. 1756

Pagina 39

44 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008USB port USB 1.1USB DeviceUSB Series B ReceptacleDeviceNet connect

Pagina 40 - Input Structure

ControlLogix DeviceNet Scanner Module 45Publication 1756-IN566D-EN-P - June 2008 Environmental SpecificationsAttribute ValueTemperature, operating

Pagina 41 - Status Structure

46 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008CertificationsCertification ValueCertifications(1)(when product is

Pagina 42

ControlLogix DeviceNet Scanner Module 47Publication 1756-IN566D-EN-P - June 2008Additional ResourcesThese documents contain additional information

Pagina 43 - Specifications

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwe

Pagina 44

ControlLogix DeviceNet Scanner Module 5Publication 1756-IN566D-EN-P - June 2008Environment and EnclosureATTENTIONThis equipment is intended for us

Pagina 45 - Environmental Specifications

6 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008North American Hazardous Location ApprovalAbout this PublicationUse

Pagina 46 - Certifications

ControlLogix DeviceNet Scanner Module 7Publication 1756-IN566D-EN-P - June 2008About the ModuleUse this figure to identify the external features o

Pagina 47 - Additional Resources

8 ControlLogix DeviceNet Scanner Module Publication 1756-IN566D-EN-P - June 2008To install these products, refer to these publications. Determine M

Pagina 48 - Rockwell Automation Support

ControlLogix DeviceNet Scanner Module 9Publication 1756-IN566D-EN-P - June 2008Change Module SettingsThe module ships with these settings.Factory