Specifications
AC (12-120V) Output Module14
Publication 1771ĆIN024B-EN-P - November 2002
Outputs per Module 16
Module Location 1771ĆA1B through ĆA4B or later I/O chassis, 1771ĆAM1, ĆAM2 chassis
Output Voltage Range 10 to 138V ac @ 47 Ć 63Hz
Output Current Rating 2A per output - not to exceed 8A per module
Surge Current (maximum) 25A per output for 100ms, repeatable every 1 second
25A per module for 100ms, repeatable every 1 second
Minimum Load Current 5mA per output
On State Voltage Drop (max.) 1.5V at load current > 50mA
5.8V at load current < 50mA
Off State Leakage Current (max.) 3.0mA per output @ 138V ac
Signal Delay (max.) Off to On
On to Off
Zero crossing 8.3ms @ 60Hz, 10.0ms @ 50Hz
Zero crossing 8.3ms @ 60Hz, 10.0ms @ 50Hz
Power Dissipation 13 Watts (max.), 1.5 Watts (min.)
Thermal Dissipation 48.0 BTU/hr (max.), 5.13 BTU/hr (min.)
Backplane Current 295mA
Isolation Voltage Tested to 2500V dc for 1s
Conductors Wire Size
Category
14-22AWG (2.5-0.25mm
2
) stranded copper wire rated at 75
o
Cor
greater
1
3/64 inch (1.2mm) insulation (max)
2
2
Environmental Conditions
Operating
Temperature
IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
32 to 140°F(0
o
to 60
o
C)
Storage Temperature IEC 60068-2-1 (Test Ab, Unpackaged, Nonoperating Cold)
IEC 60068-2-2 (Test Bb, Unpackaged, Nonoperating Dry Heat)
IEC 60068-2-14 (Test Na, Unpackaged, Nonoperating Thermal Shock)
-40 to 185°F (-40 to 85
o
C)
Relative Humidity IEC 60068-2-30 (Test Db, Unpackaged, Nonoperating Damp Heat)
5 to 95%, noncondensing
Shock
Operating
Nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30g
50g
Vibration IEC 60068-2-6 (Test Fc, Operating)
2g @ 10-500Hz
ESD Immunity IEC 61000-4-2
4kV indirect discharges
Radiated RF Immunity IEC 61000-4-3
10V/m, with 1kHz sine-wave 80% AM from 30MHz to 1000MHz
EFT/B Immunity IEC 61000-4-4
+
1kV @ 5kHz on signal ports
Surge Transient Immunity IEC 61000-4-5
+
1kV line-line (DM) and +2kV line-earth (CM) on signal ports
Conducted RF Immunity IEC 61000-4-6
10V rms with 1kHz sine wave 80% AM from 150kHz to 30MHz
Emissions CISPR 11
Group 1, Class A (with appropriate enclosure)