Rockwell-automation 1784-PCIDS DeviceNet PCI Communication Interface C Manual de usuario Pagina 46

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 45
6-2 Use the DeviceNet Test Application to Verify the Configuration
Publication 1784-IN004E-EN-P - April 2005
Start the Test Application
The test application is automatically installed as part of the driver installation procedure.
To start the test application, click Start Programs Rockwell Software IOLinx
IOLinx for DeviceNet DeviceNet Test.
If the driver cannot establish communication with the module, an error message is displayed.
Configure the Port
You must configure the port the first time you use a 1784-PCIDS card.
To configure the port, follow these steps:
1. Select Configure Port... from the Setup menu.
2. Select Allen-Bradley 1784-PCIDS from the DeviceNet Driver Selection screen.
3. Click on Select.
4. Set Node Address (0 - 63).
5. Set Baud Rate (125/250/500 kbs).
6. Click OK. You see a dialog box that tells you operation was successful, followed by a
similar message box that tells you that the port has been configured.
Vista de pagina 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 67 68

Comentarios a estos manuales

Sin comentarios