1PRE Publication 1790-IN004B-EN-P - April 2001 2003
Installation Instructions
DeviceNet Analog Base D-Shell
CompactBlock LDX I/O
(Cat. Nos. 1790D-N4C0, -N0C2, -N4V0, -N0V2)
What This Document Describes
This document describes how to install your CompactBlock
LDX™ I/O blocks.
EDS File Requirements
Current functionality of CompactBlock LDX I/O blocks requires
current modular EDS file for RSNetWorx for DeviceNet™ version
3.0 or later software.
These files are easy to install and are available online at:
www.ab.com/networks/eds/
EDS files for blocks with matching catalog numbers (for both
D-Shell and terminal block versions) are the same. Thus, on the
website and in RSNetWorx for DeviceNet, there is only one EDS
file for both versions of the blocks. For example, if you want the
EDS file for 1790D-T8BV8B, use the EDS file labled
1790D-8BV8B.
For information on: Refer to page:
EDS File Requirements below
Important User Information 2
Installing CompactBlock I/O 5
Wiring the D-Shell Connectors 8
Connecting the DeviceNet Cable 9
I/O Memory Mapping 11
Troubleshooting with the Indicators 12
Module Specifications 15
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - CompactBlock LDX I/O

1PRE Publication 1790-IN004B-EN-P - April 2001 2003Installation InstructionsDeviceNet Analog Base D-Shell CompactBlock LDX I/O(Cat. Nos. 1790D-N4C0,

Pagina 2 - Important User Information

10 Publication 1790-IN004B-EN-P - April 2003The required DeviceNet connector is not supplied with the block - you must purchase it separately

Pagina 3

11Publication 1790-IN004B-EN-P - April 2003I/O Memory Mapping1790D-N4C0, -N4V0 Input Data FileWord/Bit Descriptions for 1790D-N4C0, -N4V0 Ana

Pagina 4

12 Publication 1790-IN004B-EN-P - April 20031790D-N0C2, -N0V2 Output Data FileWord/Bit Descriptions for 1790D-N0C2, -N0V2 Analog Output Modul

Pagina 5 - Address is set at 11

13Publication 1790-IN004B-EN-P - April 2003I/O Channel LED Status Indicator1790D-N4V0 1790D-N4C0Status: Description: Status: Description:Flas

Pagina 6 - IMPORTANT

14 Publication 1790-IN004B-EN-P - April 2003I/O Channel LED Status Indicator1790D-N0V2 1790D-N0C2Status: Description: Status: Description:Fla

Pagina 7 - 7

15Publication 1790-IN004B-EN-P - April 2003DeviceNet Analog Base D-Shell Block SpecificationsThe following table contains specifications that

Pagina 8 - 8

16 Publication 1790-IN004B-EN-P - April 20031 Refer to publication 1770-4.1, Programmable Controller Wiring and Grounding Guidelines.2 See th

Pagina 9 - Connect the DeviceNet Cable

17Publication 1790-IN004B-EN-P - April 20034-Channel Analog Current Input Module Specifications1790D-N4C0Inputs per module 4 channel single-e

Pagina 10 - . A color-coded wiring

18 Publication 1790-IN004B-EN-P - April 20032 Channel Analog Current Output Module Specifications1790D-N0C2Outputs per module 2 channel singl

Pagina 11 - • No field power

19Publication 1790-IN004B-EN-P - April 20034 Channel Analog Voltage Input Module Specifications1790D-N4V0Inputs per module 4 channel single-e

Pagina 12 - • I/O status

2 Publication 1790-IN004B-EN-P - April 2003Important User InformationBecause of the variety of uses for the products described in this public

Pagina 13 - 13

20 Publication 1790-IN004B-EN-P - April 20032 Channel Analog Voltage Output Module Specifications1790D-N0V2Outputs per module 2 channel singl

Pagina 14 - 14

21Publication 1790-IN004B-EN-P - April 2003The following information applies when operating this equipment in hazardous locations:Information

Pagina 15 - 15

22 Publication 1790-IN004B-EN-P - April 2003

Pagina 16 - 16

23Publication 1790-IN004B-EN-P - April 2003

Pagina 17 - 17

Publication 1790-IN004B-EN-P - April 2003 PN957782-22Supersedes Publication 1790-IN004A-EN-P - November 2001 © 2003 Rockwell Au

Pagina 18 - Ω maximum

3Publication 1790-IN004B-EN-P - April 2003ATTENTION!Identifies information about practices or circumstances that can lead to personal injury

Pagina 19 - Ω minimum

4 Publication 1790-IN004B-EN-P - April 2003ATTENTION!Environment and EnclosureThis equipment is intended for use in a Pollution Degree 2 indu

Pagina 20

5Publication 1790-IN004B-EN-P - April 2003Installing CompactBlock LDX I/OFollow these steps to install the block:1. Set the node address on t

Pagina 21 - 21

6 Publication 1790-IN004B-EN-P - April 2003Mount the Base BlockYou can mount the base block to a panel or DIN rail. We recommend that you gro

Pagina 22 - 22

7Publication 1790-IN004B-EN-P - April 20035. Replace the block on the panel and place a screw through each of the two mounting holes. Tighten

Pagina 23 - 23

8 Publication 1790-IN004B-EN-P - April 2003Beginning with the base block, you can mount your expansion blocks either horizontally or vertical

Pagina 24

9Publication 1790-IN004B-EN-P - April 20031790D-N0C2 Current Analog Input Module Wiring Diagram for D-Shell Connector• Wire pins 17, 18 and 1