Par Parameter Name Factory Default Programmed Value
40 Motor Type Induction
41 Motor NP Volts Based on Drive Rating
42 Motor NP FLA Based on Drive Rating
43 Motor NP Hertz Based on Drive Cat. No.
44 Motor NP RPM 1750 RPM
45 Motor NP Power Based on Drive Rating
46 Mtr NP Pwr Units Based on Drive Rating
47 Motor OL Hertz Motor NP Hz/3
48 Motor OL Factor 1.00
53 Torque Perf Mode Sensrls Vect
61 Autotune Calculate
62 IR Voltage Drop Based on Drive Rating
63 Flux Current Ref Based on Drive Rating
81 Minimum Speed 0.0 Hz
82 Maximum Speed 50.0 or 60.0 Hz
83 Overspeed Limit 10.0 Hz
90 Speed Ref A Sel Analog In 2
91 Speed Ref A Hi [Maximum Speed]
92 Speed Ref A Lo 0.0 Hz
140 Accel Time 1 10.0 Secs
142 Decel Time 1 10.0 Secs
201 Language Not Selected
320 Anlg In Config 0
321 Anlg In Sqr Root 0
322 Analog In 1 Hi 10.0 Volt
323 Analog In 1 Lo 0.0 Volt
324 Analog In 1 Loss Disabled
361 Digital In1 Sel Stop - CF
362 Digital In2 Sel Start
S.M.A.R.T. Start
Parameter Setup
Customer Name ____________________
Plant ____________________
Machine # ____________________
Process Number ____________________
Other Data ____________________
Date Programmed ____________________
SW Version ____________________
Drive Cat # ____________________
Drive Ser # ____________________
Identity