2 Rockwell Automation Publication 20P-IN074A-EN-P - October 2014
PowerFlex DC Drive Frame D Series A to Series B Fan Replacement
What This Kit Includes
Fan assembly (includes fan and mounting bracket)
A portion of the data nameplate label with the new three-phase fan loss
detection board terminal names
Three-phase fan loss detection board and support
To p a i r f l o w p l a t e
Tools That You Need
T20 hexalobular screwdriver
T10 hexalobular screwdriver
13 mm socket wrench
Cable ties
Wire cutter
3.5 mm x 0.8 mm screwdriver
What You Need to Do
To replace the existing fan assembly:
Step 1: Remove power from the drive
Step 2: Remove the protective cover and top air flow plate
Step 3: Remove the existing fan assembly
Step 4: Remove the existing fan loss detection board
Step 5: Remove the existing fan starting capacitor
Step 6: Install the series B three-phase fan loss detection board
Step 7: Install the series B top air flow plate
Step 8: Replace the top protective cover and document the change
IMPORTANT
The Frame D, series B drive cooling fan requires three-phase (50/60 Hz),
400…460V AC input power. If sourced from the main three-phase AC input,
the power supply connections must be taken from the primary side of the
installed isolation transformer or line reactor (clean power).