Dataliner DL10 Message Display10
Connecting AC Power
The table below shows the electrical ratings for the Dataliner DL10 display.
Catalog Number Supply Voltage Power Consumption
2706-A41C
2706-A41J
120V ac, 60 Hz 55 VA maximum
2706-A42C
2706-A42J
240V ac, 50 Hz 55 VA maximum
!
ATTENTION: Terminal 3 (Protective Earth) must be connected to a
reliable low impedance earth ground to protect the display from electrical
noise. This ground connection will also protect personnel from electrical
shock if the electronics short to the DL10 case.
!
ATTENTION: The Dataliner DL10 display is designed for safe use
when installed in a suitably rated NEMA Type 12, 13, 4X (indoor use
only), IP54 or IP65 enclosure.
!
ATTENTION: Do not apply power to the display until all wiring
connections have been made. Failure to do so may result in electrical
shock.