3–8 Overview of Sample Application
Publication 2711-6.2
Remote I/O Application Tags
This section defines the GSRIO project tags that are used by the
Remote I/O application. These tags read or write data to bit, integer
and input/output files associated with a PLC 5/25 controller on a
Remote I/O link.
GSRIO Project Tags for Remote I/O Application
This object Uses this tag To
Motor_Start
Motor_Start_Ind
Start the motor by setting bit I:010/10 ON (1).
Control state change by monitoring bit O:010/10.
Motor_Stop
Motor_Stop_Ind
Stop the motor by setting bit I:010/11 ON (1).
Control state change by monitoring bit O:010/11.
Motor_Stop_Ind Display the current status (START or STOP) of the
motor by reading bit O:010/11.
Motor_AutoManual Set the motor to AUTO or MANUAL mode by
writing an unsigned integer value to N7:10.
Motor_AutoMan_Ind Display the current mode (AUTO or MANUAL) of
the motor by reading the data at N7:3.
Motor_Speed Enter a new motor speed (0 to 1000 rpm) by writing
an unsigned integer value to N7:13.
Motor_Spd_Notify When a new motor speed is entered, the bit at
N7:11/4 is set ON (1). The scratch pad remains
open until new motor speed is written to N7:13.
The terminal clears bit N7:11/4 when the
Motor_Spd_Handshk tag is set (ON) 1.
Motor_Spd_Handshk Sets bit N7:2/2 ON (1) when the new motor speed
is written to the Motor_Speed tag at N7:13.
The ladder logic program clears bit N7:2/2.
Motor_Speed_Ind Display the current motor speed in numeric form (0
to 1000 rpm) by reading the data at N7:1.
Motor_Speed_Ind Display the current motor speed in a graphic form
by reading the data at N7:1.
Motor_Speed_Dec Decrease the motor speed by setting bit N7:11/0 ON
(1) and OFF (0) in Manual Mode.
Motor_Speed_Inc Increase the motor speed by setting bit N7:11/1 ON
(1) and OFF (0) in Manual Mode.
Messages Trigger a message to appear in the Alarm Banner
by reading the trigger value at N7:4.