INSTALLATION INSTRUCTIONS
PHOTOSWITCH
MINIATURE SIDE VIEW
TRANSMITTED BEAM CONTROL, BULLETIN 40CA4/47CN4-4000
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PGĆ9000
BULLETIN NUMBER TYPE RESPONSE TIME
OPERATING DISTANCE
22DJ3-4000 22DJ4-4000
22DJ9-4000
22DJ9-4001
22DJ4-5000
22DJ9-5000
40CA4-4000
+
Light Source
Refer to
15 (4.57m) 40 (12.2m) 26 (7.92m)
+
47CN4-4002
Receiver
22 Series 4000
With 60-1711 Extended Lens
or
25 (7.62m) 75 (22.8m) 49 (14.93m)
40CA4-4000
+
Light Source
or
22 Series 5000
40 (12.2m) 110 (33.5m) 72 (21.94m)
+
47CN4-4003
Receiver
22
S
er
i
es
5000
With 60-1711 Extend Lens
75 (22.8m) 200 (70m) 130 (39.62m)
40CA4-4000
+
Light Source 75 (22.8m) Not Recommended Not Recommended
+
47CN4-4004
Receiver
With 60-1711 Extended Lens
140 (42.68m) Not Recommended Not Recommended
40CA4-4000
+
47CN4-4003
Diffuse 1.5 (.45m) 5 (1.52m)
SPECIFICATIONS
Field of View 5°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
with 60–1711 4.5°. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transmitting LED Infrared, 880nm. . . . . . . . . . . . . . . . . . . . . . . .
Ambient Temperature Range –40°F to 185°F (–40°C to 85°C). .
Approvals UL Listed and CSA Certified. . . . . . . . . . . . . . . . . . . .
Operating Environment NEMA 3, 4, 12, 13 and IP66 (IEC529). .
Housing High impact chemically resistant Housing. . . . . . . . . . . .
Cable
Light Source 2 conductor vinyl jacketed cable 10 (3m). . . . . . .
Receiver 2 conductor vinyl jacketed cable 10 (3m). . . . . . . . . .
OPERATING DISTANCE SELECTION
The maximum operating distance is based on installing the control
in a relatively clean environment. Normal industrial environment ac-
tually ranges from moderately dusty to extremely dirty. Greater oper-
ating margin (excess gain) may be required, which can be obtained by
reducing the operating distance of the control. (optics should be
cleaned regularly.)
TYPICAL RESPONSE CURVE
10% 20% 30% 40% 50% 100%
Percent of Maxium Operating Range
T
2
T
1
Recommended Operating
Range Derating For dirty"
Industrial Environments
Recommended Operating Range
Derating For normal" Industrial
Environments
100X
50x
40x
30x
20x
10x
5x
4x
3x
2x
1x
Transmitted Beam Operating
Range Selection
OPERATING MARGIN