1
Installation Instructions—PHOTOSWITCH
R
Series 5000 Blue Line with Analog Output
Photo Head Retroreflective Standard Diffuse Fixed Focus Wide Angle
Fiber Optic
Infrared Glass
Fiber Optic
Visible Red Plastic
Catalog Number 42DRU--5400 42DRP--5400
42DRA--5400--FF
42DRF--5400--FF
42DRA--5400--WA
42DRF--5400--WA
42DRA--5400-- FO
42DRF--5400--FO
Sensing Distance
4.6m (15ft) total
4.0m (13ft) linear
1.5m (5ft) total
1.2m (4ft) linear
(IR) 127mm (5in) max peak @ 3in
(VR) 101.6mm (4in) max peak @ 2in
(IR) 508mm (20in)
(VR) 177.8mm (7in)
Depends on fiber optic cable
Transmitting LED Infrared 880nm Infrared 880nm (42DRA) Infrared 880nm (42DRF) Visible Red 660nm Infrared 880nm Visible Red 660nm
Indicators Red: Setpoint A; Green: Setpoint B
Field of View
3_ 3_
— — Depends on fiber optic cable selected
Sensitivity Adjustment Yes
Operating Temperature
-- 4 0 _Cto+65_C(--40_Fto+150_F)
Relative Humidity 90% maximum
Housing/Lens Material Valox
/Acrylic Valox
/Acrylic
Cover Gasket Material Nitrile
Operating Environment NEMA 3, 4, 12, 13, and IP66 (IEC 529), corrosion resistant, high-impact housing
Approvals UL listed, CSA certified (except cable style power base), and CE marked for all applicable directives
Protections Output short-circuit (analog only)
Vibration 10--55 Hz, 1 mm amplitude, Meets or exceeds IEC 947--5--2
Shock 30G, Meets or exceeds IEC 947--5--2
Supply Voltage/Current 22--28V DC/70mA max
Output Type Analog 1--20mA current or 1--10V DC voltage (selectable negative or positive slope) (2) NPN setpoints (selectable)
Output Load 900 (analog current); 3K minimum (analog voltage); 28V DC, 100mA (setpoints)
Load Current 100mA
Leakage Current 10Amax.
Response Time 100ms (time required for analog swing)
Photo Base
Screw Terminal (nickel-plated brass
pressure type terminal #6--32
42DTB--5000
3m Cable (5 conductor flexible PVC
jacketed cable 3m (10ft))
42DCB--5000
Sensing modes may be field configurable by selecting either the 42DRA--5400 or 42DRF--5400 photohead and one of the following lens assemblies: 61--5551 for fixed focus sensing mode, 61--5511 for wide angle diffuse sensing
mode.
Comentarios a estos manuales