Rockwell-automation 440G-LZ Guard Locking Switch User Manual Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
Rockwell Automation Publication 440G-UM001A-EN-P — November 2013 23
Chapter 4
Description of Operation
Status/Diagnostic LEDs
During Operation
During operation, the LEDs indicate the status of the Guardmaster
440G-LZ guard locking switch as follows:
Power-to-Lock
Versions
Guard
Status
Lock
CMD
OSSD
Input
Lock
Status
LED
Status
OSSD
Status
Power on and lock
CMD off
Open or
closed
Off Off or
on
Unlocked Blinks 6x green
then solid red
Off
Lock CMD on, door
open
Open On Off or
on
Unlocked Fast flash green Off
Lock CMD on, door
closed
Closed On Off Locked Slow flash green Off
Lock CMD on, door
closed
Closed On On Locked Solid green On
Power-to-
Release Versions
Guard
Status
Lock
CMD
OSSD
Input
Lock
Status
LED
Status
OSSD
Status
Power on with
door open
Open Off Off or
on
Unlocked Blinks 6x green,
then blinks 1x
red, followed by
fast flash green
Off
Power on with
door closed
Closed Off Off Locked Blinks 6x green,
then blinks 1x
red, followed by
slow flash green
Off
Power on with
door open, and
OSSD input active
Closed Off On Locked Blinks 6x green,
then blinks 1x
red, followed by
solid green
On
Unlock CMD on,
and door closed or
open
Open or
closed
On Off or
on
Unlocked Solid red Off
Vista de pagina 22