Wiring
The sensor tip should be completely
surrounded by medium.
Position the sensor tip in the area of
maximum fluid velocity (pipe center).
Minimum sensor immersion length:
L1 ±10 mm.
Figure 4 Installation conditions
Orientation:
For horizontal pipes: lateral installation.
Note!
Installation from above (see Figure 4) only if
the pipe is completely filled with medium
during operation.
For vertical pipes: installation in the
ascending pipeline.
Installation of 839E by min. 3° inclination,
because of self draining.
Figure 5 Correct orientation
Do not install in down
pipes open towards the
end.
The sensor tip should
never touch the pipe
wall.
Figure 6 Incorrect installation
ATTENTION