Chapter 6 Advanced Reporting Topics
Select this option: If:
Table is not in a time-series format. Your table does not contain any
time-series data. This setting will
disable the time-series analysis and
FactoryTalk Transaction Manager
time-series data collection for the report
data source.
Narrow Format. All Reporting Tags in a
single column.
The reporting tag values are stored in a
single column of the table.
Wide Format. Each Reporting Tag in
separate column.
Your table has a separate column for
each reporting tag.
Compression. Your table contains compressed
time-series data that has been collected
using the FactoryTalk Transaction
Manager Compression engine.
19. Click Next.
NOTE
If you have selected the Table is not in a time-series format
option, the wizard skips to the last step of the procedure.
The Match Time-series Columns page appears.
20. Specify the role of each database field in the time-series
analysis:
If you have selected this
option:
Specify:
Narrow Format
The field that contains the reporting tag ID.
The field that contains the timestamp.
The field that contains the value.
Wide Format
One or more fields that contain the
reporting tag values.
The field that contains the timestamp.
1. Under Time-series Use, click a table cell.
2. From the list, select a role for the cell.
21. Click Next.
The Data Point Configuration Table page appears.
22. Do either of the following:
114 Rockwell Automation Publication HIST-UM001K-EN-E-June 2014