ADMINISTRATOR’S GUIDEMetric Line EditionPUBLICATION FTM LE-IN001A-EN-P–August 2008Supersedes Publication FTMLE-IN001A-EN-EINTEGRATED PRODUCTION &
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE6• • • • •To receive regular e-mail messages with links to the latest technical notes, softw
72Installing FactoryTalk Metrics LEFactoryTalk Metrics LE relies on several software packages that must be installed before you install FactoryTalk Me
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE8• • • • •Install FactoryTalk Services PlatformFactoryTalk Services Platform is installed wi
2 • INSTALLING FACTORYTALK METRICS LE9• • • • •PrerequisitesBefore installing FactoryTalk Metrics LE, you must install the following software prod
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE10• • • • •Creating a SQL Server databaseIf you do not have an existing SQL Server database
2 • INSTALLING FACTORYTALK METRICS LE11• • • • •The New Login dialog box should now look like this:3. In the Select a page pane on the left side o
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE12• • • • •5. Click OK. The new FactoryTalk Metrics LE user (for example, FTMLEUser) appears
2 • INSTALLING FACTORYTALK METRICS LE13• • • • • Server. Click the drop-down arrow to select the name of the computer where SQL Server is install
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE14• • • • •Installing FactoryTalk Metrics LEInstall FactoryTalk Metrics LE on the same compu
153FactoryTalk Metrics LE ContentFactoryTalk Metrics LE contains additional software and content which is not included in a standard FactoryTalk Metri
iiContact RockwellCustomer Support Telephone — 1.440.646.3434 Online Support — http://www.rockwellautomation.com/supportCopyright Notice© 2008 Rockwel
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE16• • • • •UDT Data Points and FactoryTalk Metrics Performance ParametersThe FactoryTalk Met
3 • FACTORYTALK METRICS LE CONTENT17• • • • • IDEAL CYCLE TIME This value is the time required for one part to past through the workcell under ide
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE18• • • • •TOTAL PARTS The Total Parts value is automatically calculated by FactoryTalk Metr
3 • FACTORYTALK METRICS LE CONTENT19• • • • •MONITORED AVAILABILITY Monitored Availability can be used as a real-time override of Scheduled Availa
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE20• • • • •CUSTOM EVENTS - DIGITALThe UDT contains an array of five Boolean values that are
3 • FACTORYTALK METRICS LE CONTENT21• • • • •CUSTOM EVENTS - ANALOGThe FTMLE_Workcell UDT contains a UDT called FTMLE_AnalogEvents — an array of o
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE22• • • • •FLEX FIELDS - STRINGA FactoryTalk Metrics application can have five flex fields.
3 • FACTORYTALK METRICS LE CONTENT23• • • • •FLEX FIELDS - BOOLEANBoolean flex fields are valid flex field types and therefore are provided in the
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE24• • • • •The primary additional report template is a dashboard report that contains nine d
254Configuring FactoryTalk Metrics LEFactoryTalk Metrics LE contains tools that are designed to reduce the time it takes to implement a FactoryTalk Me
i1 • Welcome to FactoryTalk Metrics Line Edition 1What is FactoryTalk Metrics Line Edition?. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE26• • • • • Reports. Using the standard Report Expert reports, create and manage parameter
4 • CONFIGURING FACTORYTALK METRICS LE27• • • • •Configuring the FactoryTalk DirectoryIn order to configure FactoryTalk Directory for FactoryTalk
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE28• • • • •Adding FactoryTalk usersTo create users who can access FactoryTalk Metrics, you m
4 • CONFIGURING FACTORYTALK METRICS LE29• • • • •CREATING AN APPLICATION AND SERVER FOR RSLINX ENTERPRISECreate a new application for your RSLinx
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE30• • • • •ADDING SHORTCUTS Add shortcuts to reference each of the ControlLogix controllers
4 • CONFIGURING FACTORYTALK METRICS LE31• • • • •activations to the Information Services Manager. See “Assigning user privileges, licensing, and a
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE32• • • • • Database Password. Enter the user’s password for the SQL Server database. 6. To
4 • CONFIGURING FACTORYTALK METRICS LE33• • • • •4. Click the License & Activation tab and select FactoryTalk Metrics Author checkbox. This al
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE34• • • • • String Value. Select this option because the FactoryTalk Metrics LE Configurati
4 • CONFIGURING FACTORYTALK METRICS LE35• • • • •7. To close the wizard, click Close.Creating the plant modelThere is no default plant model confi
FACTORYTALK METRICS LINE EDITION USER’S GUIDEii• • • • •4 • Configuring FactoryTalk Metrics LE 25Configuring FactoryTalk Metrics LE: New vs. Upda
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE36• • • • •4. At the workcell level of the plant model, type the name of the workcell (for e
4 • CONFIGURING FACTORYTALK METRICS LE37• • • • •6. To see the UDT’s tags, select the FTMLE_Workcell tree item. 7. Create the necessary number of
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE38• • • • •timely data. In general, the type of instruction that you will add to the program
4 • CONFIGURING FACTORYTALK METRICS LE39• • • • •1. Launch the FactoryTalk Metrics LE Configuration Tool. Select Start > Programs > Rockwell
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE40• • • • •3. Click Load from database to load the list of workcells configured in the plant
4 • CONFIGURING FACTORYTALK METRICS LE41• • • • •2. Complete the following fields: FTTM XML out. Select the location where you want to store the
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE42• • • • •an area path in the application (for example, if the OPC Server is located direct
4 • CONFIGURING FACTORYTALK METRICS LE43• • • • • With area and UDT as an array:FT.ApplicationName._AREAName::_ShortCutName_UDTName_Occurence#_.U
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE44• • • • •4. Complete the wizard to register the configuration. Be sure and select FactoryT
4 • CONFIGURING FACTORYTALK METRICS LE45• • • • •3. To update the data on this tab with the data from the FactoryTalk Metrics database, click Upda
11Welcome to FactoryTalk Metrics Line EditionWhat is FactoryTalk Metrics Line Edition?FactoryTalk Metrics LE is a special edition of FactoryTalk Metri
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE46• • • • •After you have used the FactoryTalk Metrics LE Configuration Tool: Every data po
4 • CONFIGURING FACTORYTALK METRICS LE47• • • • • Fault MetricsConfiguring ReportsAlthough FactoryTalk Metrics LE contains over 40 configured rep
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE48• • • • •FTMLE Admin Guide.book Page 48 Friday, August 8, 2008 8:28 AM
495Viewing FactoryTalk Metrics LE ReportsReport Expert is the pre-configured reporting interface for FactoryTalk Metrics LE, just as it is for Factory
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE50• • • • •Dashboard ExampleThis report consists of the Dashboard report template and the Da
5 • VIEWING FACTORYTALK METRICS LE REPORTS51• • • • • Sorting: None Plant Model: None Filtering: None TOP N: NoneMachine State HistoryThis rep
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE52• • • • •The Machine State History report uses the pre-defined parameter set named “Last 3
5 • VIEWING FACTORYTALK METRICS LE REPORTS53• • • • •Dashboard widgetsThe Dashboard Example report (see “Dashboard Example” on page 50) is compris
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE54• • • • •OEE COMPONENTSThe OEE Components widget displays the OEE % and the three OEE comp
5 • VIEWING FACTORYTALK METRICS LE REPORTS55• • • • •UPTIME VS. DOWNTIMEThe Uptime vs. Downtime widget displays the total uptime and total downtim
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE2• • • • •development, but it in no way limits the custom configuration you can perform usin
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE56• • • • •EVENT COUNT AND DURATIONThe Event Count and Duration widget displays information
5 • VIEWING FACTORYTALK METRICS LE REPORTS57• • • • •PRODUCTION SUMMARYThe Production Summary widget displays the total good parts, scrap parts, t
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE58• • • • • Sorting. With the exception of the Event Count and Duration widget, data in the
INDEX59• • • • •IndexAactivationsassigning 32addingareas 29FactoryTalk Metrics LE UDT 36FactoryTalk users 28shortcuts 30UDT 36W
FACTORYTALK METRICS LINE EDITION USER’S GUIDE60• • • • •Database Wizard 34defaultinstallation 7Digital performance parameter 20disablinge
INDEX61• • • • •IIdeal Cycle Time performance parameter 17importingFactoryTalk Metrics LE UDT 36FactoryTalk Transaction Manager configurati
FACTORYTALK METRICS LINE EDITION USER’S GUIDE62• • • • •permissionsSQL Server database 11plant modelloading 39structure 35workcells 35
INDEX63• • • • •FTMLE_Workcell.L5X 36importing 36performance parameters 16upgradingFactoryTalk Metrics 8.0 7FactoryTalk Metrics 9.0
FACTORYTALK METRICS LINE EDITION USER’S GUIDE64• • • • •FTMLE Admin Guide.book Page 64 Friday, August 8, 2008 8:28 AM
1 • WELCOME TO FACTORYTALK METRICS LINE EDITION3• • • • •There are different clients, including the RSBizWare Configuration Console and the Web-ba
FACTORYTALK METRICS LINE EDITION ADMINISTRATOR’S GUIDE4• • • • •configure FactoryTalk Metrics LE at the customer site. This document is also inten
1 • WELCOME TO FACTORYTALK METRICS LINE EDITION5• • • • •Report Expert User’s GuideReport Expert is the pre-configured reporting interface to Fact
Comentarios a estos manuales