Trusted
TM
PD-T8403
Issue 15 Jun 13 PD-T8403 1
Trusted
TM
TMR 24V dc Digital Input
Module – 40 Channel
Introduction
The Trusted
TM
TMR 24V dc Digital Input module interfaces to 40 field input devices. Fault tolerance is
achieved through a Triple Modular Redundant (TMR) architecture within the module for each of the 40
input channels.
Each field input is triplicated and the input voltage is measured using a sigma-delta input circuit. The
resulting field voltage measurement is compared to user configurable threshold voltages to determine
the reported field input state. When a line-monitoring device is installed at the field switch, the module
can detect open and short-circuit field cables. Line monitoring functions are independently configured
for each input channel. The triplicated voltage measurement, coupled with on-board diagnostic testing,
provides comprehensive fault detection and tolerance.
The module provides on-board Sequence of Events (SOE) reporting with a resolution of 1ms. A
change of state triggers an SOE entry. States are determined by voltage thresholds that can be
configured on a per channel basis.
Features
40 Triple Modular Redundant (TMR) input channels per module.
Comprehensive, automatic diagnostics and self-test.
Selectable line monitoring per channel to detect open circuit and short circuit field wiring
faults.
2500V dc optical isolation barrier.
On-board Sequence of Events (SOE) reporting with 1ms resolution.
Configurable 50/60Hz digital filtering to eliminate field induced noise.
Module can be hot-replaced on-line using dedicated Companion (adjacent) Slot or SmartSlot
(one spare slot for many modules) configurations.
Front panel input status LEDs for each channel indicate input status and field wiring faults.
Front panel module status LEDs indicate module health and operational mode (Active,
Standby, Educated)
TϋV Certified IEC61508 SIL 3
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - Module – 40 Channel

TrustedTM PD-T8403 Issue 15 Jun 13 PD-T8403 1 TrustedTM TMR 24V dc Digital Input Module – 40 Channel Introduction The TrustedTM TMR 24V dc Digital I

Pagina 2

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 10 1.3. Host Interface Unit (HIU) The HIU is the point of access to the Inter-Module Bus (IMB) for t

Pagina 3

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 11 1.5. Line Monitoring Thresholds The module determines the contact state and line fault status by

Pagina 4 - Table of Contents

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 12 The module biases each input channel by means of a 5kΩ (typical for 24V dc digital inputs) termin

Pagina 5 - Figures

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 13 2. Installation 2.1. Module Insertion/Removal CAUTION: The module contains static sensitive part

Pagina 6 - Disclaimer

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 14 2.3. Module Pinout Connections C B A 1 Smart Slot Link C Smart Slot Link B Smart Slot Link

Pagina 7 - Associated Documents

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 15 2.4. TrustedTM Module Polarisation/Keying. All TrustedTM Modules have been Keyed to prevent inser

Pagina 8 - 1. Description

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 16 3. Application 3.1. Module Configuration There is no configuration required to the physical input

Pagina 9

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 17 OEM Parameter Description Notes TICS_CHASSIS The number of the TrustedTM Chassis where the pri

Pagina 10 - 1.4. Front Panel Unit (FPU)

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 18 Value Description 7 Unknown 5 Short circuit 4 Closed contact 3 Indeterminate 2 Open contac

Pagina 11 - Module T8403

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 19 When the TMR Processor detects a 2oo3 channel fault or discrepancy, or if the input

Pagina 12 - 1.6. Housekeeping

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 2 Issue Record Issue Number Date Revised by Technical Check Authorised by Modification

Pagina 13 - 2. Installation

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 20 3.2.7. Rack 7: HKEEPING Channel Description FCR Units (Full Scale Range) 1 A 24V2 Input Volta

Pagina 14

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 21 Each input within the housekeeping rack is reported as an integer. In general, the application e

Pagina 15 - Module Polarisation/Keying

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 22 Bit 7 6 5 4 3 2 1 0 Standby Module Active Module Ejector open FCR C Healthy FCR B Health

Pagina 16 - 3. Application

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 23 4. Operation 4.1. Front Panel Status LEDs on the front of the module provide visual indicatio

Pagina 17 - 3.2.2. Rack 2: STATE

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 24 4.2. Module Status LEDS There are six module status LEDs on the module front panel; three Healthy

Pagina 18 - 3.2.3. Rack 3: AI

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 25 4.3. I/O Status LEDs There are 40 input channel status LEDs on the module front panel, one fo

Pagina 19 - 3.2.6. Rack 6: DISCREP

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 26 5. Fault Finding and Maintenance 5.1. Fault Reporting Input module faults are reported to the use

Pagina 20 - 3.2.7. Rack 7: HKEEPING

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 27 5.4. Companion Slot For a Companion Slot configuration, two adjacent slots in a TrustedTM Chassis

Pagina 21 - 3.2.8. Rack 8: Information

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 28 5.7. Transfer between Active and Standby Modules The TMR Processor is responsible for manag

Pagina 22

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 29 6. Specifications System Supply Voltage Range 20 to 32V dc Number of Inputs 40 Channels Input V

Pagina 23 - 4. Operation

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 3 This page is intentionally blank

Pagina 25 - 4.3. I/O Status LEDs

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 4 Table of Contents 1. Description ...

Pagina 26 - 5.3. Module Faults

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 5 5.6. Cold Start ...

Pagina 27 - 5.6. Cold Start

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 6 Notice The content of this document is confidential to ICS Triplex Technology Ltd. com

Pagina 28

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 7 Revision and Updating Policy All new and revised information pertinent to this document shall be i

Pagina 29 - 6. Specifications

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 8 1. Description The TrustedTM TMR 24V dc Digital Input module is a member of the TrustedTM range of

Pagina 30

TrustedTM Module T8403 Issue 15 Jun 13 PD-T8403 9 Figure 2 shows a simplified functional block diagram of the TrustedTM 24V dc Digital Input module.

Comentarios a estos manuales

Sin comentarios