PowerFlex 4M Technical Data
11
Installation Considerations
Control Wiring
The control logic is 24V DC and can be set for either Sink or Source control via a DIP switch setting.
Control terminal screws are sized for a conventional blade screw driver.
I/O Terminals 1, 2 and 3 are dedicated for Stop, Start and Reverse operation respectively. These I/O Terminals can be
programmed for 2- or 3-Wire operation to meet application requirements.
I/O Terminals 4 and 5 are programmable and provide added flexibility. Programmable functions include:
- Local Control
- Preset Frequencies
- Jog
- RS485 Control
- Second Accel/Decel
- Auxiliary Fault
- Clear Fault
Speed can be controlled via a 0-10V input or 4-20 mA input. Both are electrically isolated from the drive.
One form C relay can be programmed to provide the status of a wide variety of drive conditions. The drive is shipped
with a jumper installed between I/O Terminals 01 and 11 to allow out of box operation from the keypad.