Rockwell Automation PicoTM Controller 1760 Manual de usuario Pagina 47

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 158
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 46
Publication 1760-UM001A-EN-P
Drawing a Circuit Diagram with Pico 4-7
.
Pico leaves the Enter mode when you press the left or right arrow keys or Ok.
Deleting Contacts and Relay Coils
1.
1.1.
1. Move the cursor using the arrow buttons to a contact or coil field.
2. Press Del.
The contact or the relay coil is deleted, together with any connections.
Changing Make Contacts into Break Contacts
Every relay contact in the circuit diagram can be defined as either a make or break
contact.
1.
1.1.
1. Move the cursor over the contact and press Enter to change to the enter mode.
2. Press Alt. The make contact changes to a break contact.
3. Press Ok twice to confirm the change.
Change I1 to I2 in the
contact field
Change {Q1 to {Q8 in the coil
field
I1
Q
M
C
T
P
D
S
:
R
I1
2
3
4
5
.
.
.
16
I2
{Q1
S
R
{Q1
M
T
C
D
S
:
{Q1
2
3
.
.
.
8
{Q8
OK
OK
I2----------{Q4
I3
I2----------{Q4
I3
I2----------{Q4
I3
ALT
2 X
Vista de pagina 46