Topic Page
Important User Information 2
Power Requirements 8
Interconnect Limit 8
Wiring Requirements 9
Grounding Requirements 9
Mounting on the DIN Rail 14
Wiring 17
Specifications 19
F
OR
X
M
-
1
2
0
.
.
.
1
2
4
ON
L
Y
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - Terminal Base

XM-940 Dynamic Measurement Terminal BaseCatalog Number 1440-TB-AInstallation InstructionsTopic PageImportant User Information 2Power Requirements 8Int

Pagina 2 - Important User Information

10 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013XM System DIN Rail Grounding 1 Use 2.1 mm2 (14 AWG) wire.2

Pagina 3 - Publication

XM-940 Dynamic Measurement Terminal Base 11Publication GMSI10-IN020C-EN-P - October 2013The grounding wire can be connected to the DIN rail by usi

Pagina 4 - ATTENTION

12 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013Transducer GroundingMake certain the transducers are elect

Pagina 5

XM-940 Dynamic Measurement Terminal Base 13Publication GMSI10-IN020C-EN-P - October 2013DeviceNet Grounding - XM-124 Module OnlyThe DeviceNet netw

Pagina 6

14 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013Mounting on the DIN RailYou can also mount the terminal ba

Pagina 7

XM-940 Dynamic Measurement Terminal Base 15Publication GMSI10-IN020C-EN-P - October 20133. Hook the lip on the rear of the terminal base onto the

Pagina 8 - Interconnect Limit

16 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013Interconnecting Terminal Base UnitsFollow the steps below

Pagina 9 - Grounding Requirements

XM-940 Dynamic Measurement Terminal Base 17Publication GMSI10-IN020C-EN-P - October 2013WiringTerminal AssignmentsIMPORTANTFor more wiring connect

Pagina 10 - XM System DIN Rail Grounding

18 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 20131Terminals are internally connected and isolated from the

Pagina 11 - 24V Common Grounding

XM-940 Dynamic Measurement Terminal Base 19Publication GMSI10-IN020C-EN-P - October 2013SpecificationsThe following table lists the technical spec

Pagina 12 - Transducer Grounding

2 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013Important User InformationSolid-state equipment has operati

Pagina 13 - Switch Input Grounding

20 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013Environmental SpecificationsAttribute 1440-TB-ATemperature

Pagina 14 - Mounting on the DIN Rail

XM-940 Dynamic Measurement Terminal Base 21Publication GMSI10-IN020C-EN-P - October 2013CertificationsCertification(1) 1440-TB-Ac-UL-us Listed for

Pagina 15

Publication GMSI10-IN020C-EN-P - October 2013 PN-218584Supersedes Publication GMSI10-IN020B-EN-P - January 2013 Copyright © 2013 Rockwell Automation,

Pagina 16 - IMPORTANT

XM-940 Dynamic Measurement Terminal Base 3Publication GMSI10-IN020C-EN-P - October 2013ATTENTIONEnvironment and EnclosureThis equipment is intende

Pagina 17 - Terminal Assignments

4 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013ATTENTIONPreventing Electrostatic DischargeThis equipment i

Pagina 18

XM-940 Dynamic Measurement Terminal Base 5Publication GMSI10-IN020C-EN-P - October 2013North American Hazardous Location ApprovalThe following inf

Pagina 19 - Specifications

6 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013European Hazardous Location ApprovalEuropean Zone 2 Certifi

Pagina 20 - Environmental Specifications

XM-940 Dynamic Measurement Terminal Base 7Publication GMSI10-IN020C-EN-P - October 2013WARNING• This equipment shall be mounted in an ATEX-certifi

Pagina 21

8 XM-940 Dynamic Measurement Terminal Base Publication GMSI10-IN020C-EN-P - October 2013Power RequirementsRefer to the XM-124 Standard Dynamic Meas

Pagina 22 - Documentation Feedback

XM-940 Dynamic Measurement Terminal Base 9Publication GMSI10-IN020C-EN-P - October 2013Wiring RequirementsUse solid or stranded wire. All XM wirin

Comentarios a estos manuales

Sin comentarios