VI. Conversion Module Re-assembly After Fuse Insertion/Replacement (Continued)
2) Take the module case half with the locking tab and partially insert the tab into the mating slot of the other half.
3) At the other end of the module case, ensure the bottom guide/retainer clears the top locking extension. Push the
2 case halves up and in until you here the locking tab snap into place.
4) Replace the module case screw [(maximum torque 0.7 Nm (6.9 lb-in)].
10000021848 (Version 00)
Locking Tab: Partially Inserted
Extension
Guide / retainer