Product Overview 1-5
Preset Slow Speed
This option can be used in applications that require a slow speed jog
for general purpose positioning. Preset Slow Speed provides either
7% of base speed (low) or 15% of base speed (high) settings in the
forward direction. Reverse can also be programmed and offers 10%
of base speed (low) and 20% of base speed (high) settings.
Figure 1.6 Preset Slow Speed
S
tar
t
R
un
1
00%
M
o
t
o
r
S
p
ee
d
Time
(
seconds
)
15% - Hi
gh
7
%
- Lo
w
1
0%
- Lo
w
20% - Hi
gh
Forw
a
r
d
R
e
v
e
r
se
ATTENTION
!
Slow speed running is not intended for continuous
operation due to reduced motor cooling.