POINT I/O ControlNet Adapter1734-ACNRUser Manual
Publication 1734-UM008B-EN-P - August 2005Preface P-4TerminologyThe following table lists ControlNet terminology used throughout this manual.Te
Publication 1734-UM008B-EN-P - August 2005A-38 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-232ASC1 Channel ASCII Interface M
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-39Transmit Data / Receive Data / Delimit
Publication 1734-UM008B-EN-P - August 2005A-40 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-232ASC1 Channel ASCII Interface M
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-41Transmit Record Number/ Receive Record
Publication 1734-UM008B-EN-P - August 2005A-42 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceNotes:
Publication 1734-UM008B-EN-P - August 2005IndexNumbers1734-ACNRconfigure 4-1controller tag reference A-1diagnostic indicators 1-2diagnostics 5-1featur
Publication 1734-UM008B-EN-P - August 20052 IndexII/O connections 3-1I/O modulesinstalling 2-4indicators 5-1installing 2-1adapter 2-2connect te
Publication CIG-CO521C-EN-P- May 2003 PN957782-91How Are We Doing?Your comments on our technical publications will help us serve you better in the fu
Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST
1 Publication 1734-UM008B-EN-P - August 2005Chapter 1About the ModuleChapter ObjectivesThis chapter describes the ControlNet adapter (Catalog Number 1
Publication 1734-UM008B-EN-P - August 2005 1 PN 957974-14Copyright © 2005 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.Rockwel
Publication 1734-UM008B-EN-P - August 20051-2 About the ModuleFor a description of the diagnostic indicators and status display and how to use
1 Publication 1734-UM008B-EN-P - August 2005Chapter 2Install Your AdapterChapter ObjectivesThis chapter describes the procedures for installing your a
Publication 1734-UM008B-EN-P - August 20052-2 Install Your AdapterSet the Node AddressSet the node address using the 2-position thumbwheel swit
Publication 1734-UM008B-EN-P - August 2005Install Your Adapter 2-3Wire the Adapter ATTENTIONDo not discard the end cap. Use this end cap to
Publication 1734-UM008B-EN-P - August 20052-4 Install Your Adapter See the figure to guide you in wiring the adapter.ModuleStatusPointBusS
Publication 1734-UM008B-EN-P - August 2005Install Your Adapter 2-5Connect Programming Terminals to the Network via the NAPYou can connect progr
Publication 1734-UM008B-EN-P - August 20052-6 Install Your AdapterInstall the I/O ModulesAfter installing and wiring the adapter, install the P
Publication 1734-UM008B-EN-P - August 2005Install Your Adapter 2-71. Remove the existing adapter from the DIN rail as follows.A. Disconnect the
Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
Publication 1734-UM008B-EN-P - August 20052-8 Install Your Adapter8. Reinsert the terminal block by rotating the terminal block into the wiring
1 Publication 1734-UM008B-EN-P - August 2005Chapter 3Plan to Use Your AdapterChapter ObjectivesThis chapter explains how the adapter operates on a Con
Publication 1734-UM008B-EN-P - August 20053-2 Plan to Use Your AdapterWhen the 1734-ACNR adapter cannot support any more connections, it does n
Publication 1734-UM008B-EN-P - August 2005Plan to Use Your Adapter 3-3Connection Limit Exceeded ErrorThe connection limit exceeded error (0x011
Publication 1734-UM008B-EN-P - August 20053-4 Plan to Use Your AdapterRack ConnectionsA rack connection supports a group of modules. The 1734-A
Publication 1734-UM008B-EN-P - August 2005Plan to Use Your Adapter 3-5Direct ConnectionsThe 1734-ACNR adapter supports up to 25 direct connecti
Publication 1734-UM008B-EN-P - August 20053-6 Plan to Use Your AdapterUnconnected messaging lets tools or controllers interface with the CIP ob
Publication 1734-UM008B-EN-P - August 2005Plan to Use Your Adapter 3-7The ControlNet system places your scheduled transfers in the first part o
Publication 1734-UM008B-EN-P - August 20053-8 Plan to Use Your AdapterConfigure AutobaudThe adapter cannot reconfigure an I/O module that you p
Publication 1734-UM008B-EN-P - August 2005Plan to Use Your Adapter 3-9• POINT I/O configuration by itself (number and types of modules)• Type o
1 Publication 1734-UM008B-EN-P - August 2005Summary of ChangesThis publication contains new and revised information not in the last release.Revised In
Publication 1734-UM008B-EN-P - August 20053-10 Plan to Use Your AdapterWhen using I/O modules with large amounts of data, be aware of the 1734-
1 Publication 1734-UM008B-EN-P - August 2005 Chapter 4Configure the AdapterChapter ObjectivesThis chapter guides you through the steps required to con
Publication 1734-UM008B-EN-P - August 20054-2 Configure the AdapterThe 1784-PCC module is the Personal Computer ControlNet network interface ca
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-3
Publication 1734-UM008B-EN-P - August 20054-4 Configure the AdapterSelect a Communication Module1. Click on I/O Configuration on the left side
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-55. Click OK to see the New Module dialog.6. Complete the following entries.•
Publication 1734-UM008B-EN-P - August 20054-6 Configure the AdapterSelect the 1734-ACNR Adapter1. From the following dialog, right-click on Con
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-7• Name• Node • Description (optional) 6. Click the Open Module Properties bo
Publication 1734-UM008B-EN-P - August 20054-8 Configure the AdapterTo identify individual 1734 I/O module publications, use the list of publica
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-9Add Analog, Digital, Other, or Specialty Modules Select Analog, Digital, Oth
Publication 1734-UM008B-EN-P - August 2005Summary of Changes 2Notes:
Publication 1734-UM008B-EN-P - August 20054-10 Configure the Adapter3. Choose 1734-OB2E/C from the list of modules.4. Click OK to see the New M
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-11• Listen-Only - Rack Optimization8. Click OK. Notice that 1734-OB2E is now
Publication 1734-UM008B-EN-P - August 20054-12 Configure the Adapter• Connection• Module Info• Fault/Program Action• ConfigurationFor details o
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-1314. Choose Module Info to see this dialog, which provides identification an
Publication 1734-UM008B-EN-P - August 20054-14 Configure the Adapter3. From the Who Active dialog, choose Set Project Path.4. From the Who Acti
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-15Notice that the 1756-CNBR Bridge is now on line, but the rest of the I/O co
Publication 1734-UM008B-EN-P - August 20054-16 Configure the Adapter3. Click Set Chassis Size in Module.Note that these chassis sizes do not ma
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-176. Click Apply to update the value in the chassis size module.7. Click the
Publication 1734-UM008B-EN-P - August 20054-18 Configure the Adapter5. Choose the PCC interface card.6. Click OK.When you are online, you’ll se
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-197. Click OK.8. Choose Edits Enabled in the top left of the dialog.9. From t
v Publication 1734-UM008B-EN-P - August 2005Table of ContentsPrefacePrefaceWho Should Use This Manual . . . . . . . . . . . . . . . . . . . . . . P-1
Publication 1734-UM008B-EN-P - August 20054-20 Configure the Adapter13. Specify a value for Media Redundancy on channel A, B or A and B.14. Cli
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-2119. Notice that all of the yellow warning triangles are gone in the I/O Con
Publication 1734-UM008B-EN-P - August 20054-22 Configure the Adapter• ACNR:1:C (1734-OB2E module) configuration data• ACNR:1:I (1734-OB2E modul
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-23• ACNR:2:I (1734-IB2 module) input data• ACNR:3:C (1734-IE2V module) config
Publication 1734-UM008B-EN-P - August 20054-24 Configure the Adapter• ACNR:3:I (1734-IE2V module) input data• ACNR:I or ACNR:O (rack optimized
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-25In this example, the 1734-ACNR adapter is using 2 rack optimized connection
Publication 1734-UM008B-EN-P - August 20054-26 Configure the Adapter7. Click Apply.8. Click OK to confirm disabling the connection.The connecti
Publication 1734-UM008B-EN-P - August 2005Configure the Adapter 4-27Note that the connection status is now running.Recover from an Overloaded 1
Publication 1734-UM008B-EN-P - August 20054-28 Configure the Adapter• The 1734-ACNR adapter removes all of its ControlNet connections.• The 173
1 Publication 1734-UM008B-EN-P - August 2005Chapter 5DiagnosticsUse the Indicators to Troubleshoot Use these indicators to help troubleshoot problems
vi Publication 1734-UM008B-EN-P - August 2005Chapter 4Configure the AdapterChapter Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Publication 1734-UM008B-EN-P - August 20055-2 DiagnosticsIndication Probable CauseModule StatusOff No power applied to deviceAlternating Red/Gr
Publication 1734-UM008B-EN-P - August 2005Diagnostics 5-3POINTBus StatusOff Device not powered - check module status indicatorAlternating Red/G
Publication 1734-UM008B-EN-P - August 20055-4 DiagnosticsNotes:
1 Publication 1734-UM008B-EN-P - August 2005Appendix A1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734 POINT I/O Catalog Numbers1734 POI
Publication 1734-UM008B-EN-P - August 2005A-2 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceNote that all POINT I/O modules must be
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-3Discrete 2 POINT Input* POINT I/O Modul
Publication 1734-UM008B-EN-P - August 2005A-4 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceDiscrete 4 POINT Input* POINT I/O Modul
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-5Filter Time NoteTo enter Filter values
Publication 1734-UM008B-EN-P - August 2005A-6 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceDiscrete 2 POINT Output – With Over Loa
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-7Discrete 2 POINT Output – With Over Loa
1 Publication 1734-UM008B-EN-P - August 2005PrefaceRead this preface to familiarize yourself with the rest of the manual. It provides information conc
Publication 1734-UM008B-EN-P - August 2005A-8 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceDiscrete 4 POINT Output – With Over Loa
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-9Discrete 4 POINT Output – With Over Loa
Publication 1734-UM008B-EN-P - August 2005A-10 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceAnalog 2 Channel Input1734-IE2C2 Chann
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-111734-IE2C2 Channel Analog Current Inpu
Publication 1734-UM008B-EN-P - August 2005A-12 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-IE2V2 Channel Analog Voltage Inpu
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-131734-IE2V2 Channel Analog Voltage Inpu
Publication 1734-UM008B-EN-P - August 2005A-14 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-IR22 Channel RTD InputConfigurati
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-151734-IR22 Channel RTD InputConfigurati
Publication 1734-UM008B-EN-P - August 2005A-16 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-IT22 Channel Thermocouple Input,
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-171734-IT22 Channel Thermocouple Input,
Publication 1734-UM008B-EN-P - August 2005Preface P-2Related DocumentationThe following documents contain additional information concerning All
Publication 1734-UM008B-EN-P - August 2005A-18 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-IT22 Channel Thermocouple Input,
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-19Analog 2 Channel Output1734-OE2C2 Chan
Publication 1734-UM008B-EN-P - August 2005A-20 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-OE2C2 Channel Analog Current Outp
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-211734-OE2V2 Channel Analog Voltage Outp
Publication 1734-UM008B-EN-P - August 2005A-22 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-OE2V2 Channel Analog Voltage Outp
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-23Specialty I/O1734-VHSC241 Channel 15-2
Publication 1734-UM008B-EN-P - August 2005A-24 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-VHSC241 Channel 15-24V DC Very Hi
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-25To enter values from +128 to +255, use
Publication 1734-UM008B-EN-P - August 2005A-26 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceStored Data Note:To interpret values f
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-27Program Fault NoteProgramming Fault Er
Publication 1734-UM008B-EN-P - August 2005Preface P-3Common Techniques Used in This ManualWe use the following conventions throughout this manu
Publication 1734-UM008B-EN-P - August 2005A-28 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-VHSC241 Channel 15-24V DC Very Hi
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-291734-IJ1 Channel 5V DC Encoder / Count
Publication 1734-UM008B-EN-P - August 2005A-30 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceTo enter values from +128 to +255, use
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-31Stored Data Note:To interpret values f
Publication 1734-UM008B-EN-P - August 2005A-32 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceProgram Fault NoteProgramming Fault Er
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-331734-IJ1 Channel 5V DC Encoder / Count
Publication 1734-UM008B-EN-P - August 2005A-34 1734-POINT I/O Module/RSLogix5000 Controller Tag Reference1734-SSI1 Channel Synchronous Serial I
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-35SSI Word Delay Time Note:To enter Dela
Publication 1734-UM008B-EN-P - August 2005A-36 1734-POINT I/O Module/RSLogix5000 Controller Tag ReferenceCompare 0,1 Value Note:To enter Compar
Publication 1734-UM008B-EN-P - August 20051734-POINT I/O Module/RSLogix5000 Controller Tag Reference A-37Present / Latched Data Note:To interpr