Installation Instructions
1734 POINT I/O EtherNet/IP Adapter
Catalog number 1734-AENT, Series B
Table of Contents
Topic Page
Important User Information 2
Environment and Enclosure 3
Preventing Electrostatic Discharge 3
Additional Resources 4
North American Hazardous Location Approval 5
European Hazardous Location Approval 6
About The Adapter 7
Before You Begin 8
Determine Compatibility 8
Understand Messaging 8
Configure Autobaud 8
Install the Adapter 9
Set the Network Address 11
Replace The Adapter 13
Wire The Adapter 15
Interpret Status Indicators 17
Specifications 19
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Installation Instructions

Installation Instructions1734 POINT I/O EtherNet/IP AdapterCatalog number 1734-AENT, Series BTable of ContentsTopic PageImportant User Information 2E

Pagina 2 - Important User Information

10 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 20132. Press down firmly to install the adapter on a DIN rail, noting

Pagina 3 - Environment and Enclosure

1734 POINT I/O EtherNet/IP Adapter 11Publication 1734-IN042B-EN-P - October 2013Set the Network AddressThe thumbwheel switches are set to 999 and

Pagina 4 - Additional Resources

12 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013If you set the switches to an invalid number (for example, 000 or

Pagina 5

1734 POINT I/O EtherNet/IP Adapter 13Publication 1734-IN042B-EN-P - October 2013Replace The AdapterUse these procedures to install a replacement a

Pagina 6

14 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 20139. Press firmly to seat the adapter on the DIN rail, noting that t

Pagina 7 - About The Adapter

1734 POINT I/O EtherNet/IP Adapter 15Publication 1734-IN042B-EN-P - October 2013Wire The AdapterIMPORTANTDo not connect 120/240V AC power to this

Pagina 8 - Before You Begin

16 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013WARNING: Do not wire more than two conductors on any single termin

Pagina 9 - Install the Adapter

1734 POINT I/O EtherNet/IP Adapter 17Publication 1734-IN042B-EN-P - October 2013Interpret Status IndicatorsRefer to the following diagram and tabl

Pagina 10

18 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013Network ActivityOff No link established.Flashing green/Off Transmi

Pagina 11 - Set the Network Address

1734 POINT I/O EtherNet/IP Adapter 19Publication 1734-IN042B-EN-P - October 2013SpecificationsPOINT I/O EtherNet/IP Adapter — 1734-AENT, Series BA

Pagina 12 - DHCP State Adapter Action

2 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013Important User InformationSolid-state equipment has operational cha

Pagina 13 - Replace The Adapter

20 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013Input overvoltage protection Reverse polarity protectedPOINTBus ou

Pagina 14

1734 POINT I/O EtherNet/IP Adapter 21Publication 1734-IN042B-EN-P - October 2013Module input 10...28V DC @ 1000 mAPOINTBus output, max 5V DC @ 1.0

Pagina 15 - Wire The Adapter

22 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013Vibration IEC 60068-2-6 (Test Fc, Operating): 5 g @ 10...500 HzSho

Pagina 16

1734 POINT I/O EtherNet/IP Adapter 23Publication 1734-IN042B-EN-P - October 2013CertificationsCertification (when product is marked)(1)Valuec-UL-u

Pagina 17 - Interpret Status Indicators

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellau

Pagina 18 - Indicator Status for Modules

1734 POINT I/O EtherNet/IP Adapter 3Publication 1734-IN042B-EN-P - October 2013Environment and EnclosurePreventing Electrostatic DischargeATTENTIO

Pagina 19 - Specifications

4 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013Additional ResourcesIf you would like a manual, you can:• download

Pagina 20 - Power Supply

1734 POINT I/O EtherNet/IP Adapter 5Publication 1734-IN042B-EN-P - October 2013North American Hazardous Location ApprovalThe following information

Pagina 21 - Environmental Specifications

6 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013European Hazardous Location ApprovalThe following applies when the

Pagina 22

1734 POINT I/O EtherNet/IP Adapter 7Publication 1734-IN042B-EN-P - October 2013About The AdapterThe Series B 1734-AENT POINT I/O EtherNet/IP Adapt

Pagina 23 - Certifications

8 1734 POINT I/O EtherNet/IP Adapter Publication 1734-IN042B-EN-P - October 2013Before You BeginTo effectively use your adapter, note the following

Pagina 24 - Documentation Feedback

1734 POINT I/O EtherNet/IP Adapter 9Publication 1734-IN042B-EN-P - October 2013Install the AdapterFollow this procedure to install the adapter on

Comentarios a estos manuales

Sin comentarios