Rockwell-automation 1734-IE8C Installation Instructions Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1734-IE8C Installation Instructions. Rockwell Automation 1734-IE8C Installation Instructions User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Installation Instructions
POINT I/O 8 Channel High Density Current
Input Module
Catalog Number 1734-IE8C
Topic Page
Important User Information 2
Environment and Enclosure 3
Prevent Electrostatic Discharge 4
European Hazardous Location Approval 5
North American Hazardous Location Approval 6
Before You Begin 7
Install the Mounting Base 8
Install the I/O Module 9
Install the Removable Terminal Block (RTB) 11
Remove a Mounting Base 11
Communicating with Your Module 12
Wiring the Input Analog Module 14
Wiring Diagram 14
Interpret the Indicators 15
Specifications 17
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Input Module

Installation InstructionsPOINT I/O 8 Channel High Density Current Input ModuleCatalog Number 1734-IE8C Topic PageImportant User Information 2Environm

Pagina 2 - Important User Information

10 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 20101734-TOP Base1. Using a bladed screwdriver, r

Pagina 3 - Environment and Enclosure

POINT I/O 8 Channel High Density Current Input Modules 11Publication 1734-IN033B-EN-P - November 2010Install the Removable Terminal Block (RTB)A r

Pagina 4

12 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Install a 1734-TOPS Base1. Position the base

Pagina 5

POINT I/O 8 Channel High Density Current Input Modules 13Publication 1734-IN033B-EN-P - November 2010Default Data Map for the 1734-IE8C Analog Inp

Pagina 6

14 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Wiring the Input Analog ModuleWiring Diagram

Pagina 7 - Before You Begin

POINT I/O 8 Channel High Density Current Input Modules 15Publication 1734-IN033B-EN-P - November 2010 Interpret the Indicators Indicator State De

Pagina 8 - Install the Mounting Base

16 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Network statusOff Device is not on-line- Devi

Pagina 9 - Install the I/O Module

POINT I/O 8 Channel High Density Current Input Modules 17Publication 1734-IN033B-EN-P - November 2010Specifications IMPORTANTNote that the

Pagina 10 - 1734-TOP Base

18 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Input impedance/resistance conversion type60

Pagina 11 - Remove a Mounting Base

POINT I/O 8 Channel High Density Current Input Modules 19Publication 1734-IN033B-EN-P - November 2010General SpecificationsAttribute ValueModule l

Pagina 12 - Remove a 1734-TOPS Base

2 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Important User Information Solid state equipme

Pagina 13 - Message size: 24 Bytes

20 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Environmental SpecificationsAttribute ValueTe

Pagina 14 - Wiring Diagram

POINT I/O 8 Channel High Density Current Input Modules 21Publication 1734-IN033B-EN-P - November 2010EFT/B immunity IEC 61000-4-4:±3 kV at 5 kHz o

Pagina 15 - Interpret the Indicators

22 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Additional ResourcesThese documents contain a

Pagina 16

POINT I/O 8 Channel High Density Current Input Modules 23Publication 1734-IN033B-EN-P - November 2010Notes:

Pagina 17 - Specifications

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://support.rockwe

Pagina 18 - Input Specifications

POINT I/O 8 Channel High Density Current Input Modules 3Publication 1734-IN033B-EN-P - November 2010Environment and Enclosure ATTENTIONThis equip

Pagina 19 - General Specifications

4 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010Prevent Electrostatic Discharge ATTENT

Pagina 20 - Environmental Specifications

POINT I/O 8 Channel High Density Current Input Modules 5Publication 1734-IN033B-EN-P - November 2010European Hazardous Location Approval European

Pagina 21 - Certifications

6 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010North American Hazardous Location Approval Th

Pagina 22 - Additional Resources

POINT I/O 8 Channel High Density Current Input Modules 7Publication 1734-IN033B-EN-P - November 2010Before You BeginNote that this series C produc

Pagina 23

8 POINT I/O 8 Channel High Density Current Input Modules Publication 1734-IN033B-EN-P - November 2010 Install the Mounting BaseTo install the mount

Pagina 24 - Installation Assistance

POINT I/O 8 Channel High Density Current Input Modules 9Publication 1734-IN033B-EN-P - November 2010Install the I/O ModuleThe module can be instal

Comentarios a estos manuales

Sin comentarios