ProcessLinx OPC
Server to Server
Software
1757-PROCESSLINX
User Manual
Vista de pagina 0
1 2 3 4 5 6 ... 69 70

Indice de contenidos

Pagina 1 - Software

ProcessLinx OPC Server to Server Software1757-PROCESSLINXUser Manual

Pagina 2 - Important User Information

Publication 1757-UM002B-EN-P - January 20031-2 Setup ProceduresIn order for ProcessLinx to connect to the ProcessLogix OPC Server over the netw

Pagina 3 - Functional Description

Publication 1757-UM002B-EN-P - January 2003Setup Procedures 1-3Configure the OPC Server(s)Before ProcessLinx can work properly in runtime, each

Pagina 4

Publication 1757-UM002B-EN-P - January 20031-4 Setup Proceduresps_user accounts on them. Refer to the sections in Knowledge Builder, About Proc

Pagina 5 - Technical Support

Publication 1757-UM002B-EN-P - January 2003Setup Procedures 1-52. Type regsvr32 opcproxy.dll in the Run dialog box.3. On the server machine, go

Pagina 6 - Conventions

Publication 1757-UM002B-EN-P - January 20031-6 Setup ProceduresNotes:

Pagina 7 - Table of Contents

1 Publication 1757-UM002B-EN-P - January 2003Chapter 2 Getting StartedThis section provides the required information to setup and configure both the P

Pagina 8 - Table of Contents ii

Publication 1757-UM002B-EN-P - January 20032-2 Getting StartedRuntime ModeTo change ProcessLinx to runtime select Mode ⇒ Runtime, click or pres

Pagina 9 - Setup Procedures

Publication 1757-UM002B-EN-P - January 2003Getting Started 2-3Configure ProcessLinx OptionsTo configure ProcessLinx Options select from the Uti

Pagina 10 - External OPC Server

Publication 1757-UM002B-EN-P - January 20032-4 Getting Starteda remote server connection is lost, ProcessLinx may keep trying to connect with i

Pagina 11 - Accounts

Publication 1757-UM002B-EN-P - January 2003Getting Started 2-5Number of Retries for Redundancy / OPC Server SwitchoverThis option specifies the

Pagina 12 - 1-4 Setup Procedures

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Pagina 13 - Setup Procedures 1-5

Publication 1757-UM002B-EN-P - January 20032-6 Getting StartedNotes:

Pagina 14 - 1-6 Setup Procedures

1 Publication 1757-UM002B-EN-P - January 2003Chapter 3ProcessLinx TagMap ConfigurationA ProcessLinx TagMap configuration is created to communicate OPC

Pagina 15 - Getting Started

Publication 1757-UM002B-EN-P - January 20033-2 ProcessLinx TagMap ConfigurationCreating a ProcessLinx ConfigurationOpening a ProcessLinx Config

Pagina 16 - Runtime Mode

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-3Name blank or set it to “localHost”. Included in ProcessLinx 2.0

Pagina 17 - Configure ProcessLinx

Publication 1757-UM002B-EN-P - January 20033-4 ProcessLinx TagMap ConfigurationFigure 3.1 Pipe Properties Dialog BoxUsing the Pipe Properties d

Pagina 18 - Interface Error Log Directory

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-5EnableThe enable checkbox enables or disables the Pipe and all o

Pagina 19 - Getting Started 2-5

Publication 1757-UM002B-EN-P - January 20033-6 ProcessLinx TagMap ConfigurationUse v1.0 OPC InterfacesThe Use v1.0 OPC Interfaces checkbox indi

Pagina 20 - 2-6 Getting Started

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-7Attempt Failover if all OPC Items are Bad QualityThis checkbox w

Pagina 21

Publication 1757-UM002B-EN-P - January 20033-8 ProcessLinx TagMap Configuration• If just one of those active tags is GOOD or QUESTIONABLE quali

Pagina 22 - Creating a Pipe

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-9The number of Groups you can add is limited by memory and possib

Pagina 23

1 Publication 1757-UM002B-EN-P - January 2003PrefaceIntroductionThis document provides an overview of the ProcessLinx application. ProcessLinx allows

Pagina 24

Publication 1757-UM002B-EN-P - January 20033-10 ProcessLinx TagMap ConfigurationData Flow DirectionThe available data flow directions between t

Pagina 25

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-11Creating a TagMapTagMap definitions are created within a parent

Pagina 26

Publication 1757-UM002B-EN-P - January 20033-12 ProcessLinx TagMap Configuration2. Select Edit ⇒ Add TagMap... from the main menu or right mous

Pagina 27

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-13Attributes are specified as part of defining the TagMap in the

Pagina 28 - Creating a Group

Publication 1757-UM002B-EN-P - January 20033-14 ProcessLinx TagMap ConfigurationTable 3.C TagMap Data AttributesAttribute DescriptionServer The

Pagina 29

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-15Creating a ProcessLinx TagMap ConfigurationOnce you create the

Pagina 30

Publication 1757-UM002B-EN-P - January 20033-16 ProcessLinx TagMap ConfigurationBy default, ProcessLinx attempts to use the item file when brow

Pagina 31 - Creating a TagMap

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-17under the function blocks. Note: Some of the items are not conn

Pagina 32

Publication 1757-UM002B-EN-P - January 20033-18 ProcessLinx TagMap ConfigurationSome of the main parameter names along with their data types fo

Pagina 33 - IMPORTANT

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-19ProcessLogix Control Point parameters are dependant upon the ty

Pagina 34

Publication 1757-UM002B-EN-P - January 2003P-2• Tag Map configurations are stored in a serialized compact binary file.• Supports ability to easily imp

Pagina 35

Publication 1757-UM002B-EN-P - January 20033-20 ProcessLinx TagMap ConfigurationPVEUHIVT_R4 Read onlyKVT_R4KLINVT_R4KVT_R4T1VT_R4T2VT_R4CVEULOV

Pagina 36

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-21Translation TableTo enable scaling for a particular TagMap, you

Pagina 37 - OPC Items

Publication 1757-UM002B-EN-P - January 20033-22 ProcessLinx TagMap Configuration• To add or edit a new translation value map for the selected t

Pagina 38

Publication 1757-UM002B-EN-P - January 2003ProcessLinx TagMap Configuration 3-23If you hold down the <Control> key before you drop the ob

Pagina 39

Publication 1757-UM002B-EN-P - January 20033-24 ProcessLinx TagMap Configurationbrowse capability the External Server must be registered on the

Pagina 40

1 Publication 1757-UM002B-EN-P - January 2003Chapter 4ProcessLinx Runtime OperationEach Pipe created in ProcessLinx provides a conduit to pass informa

Pagina 41 - Translation Table

Publication 1757-UM002B-EN-P - January 20034-2 ProcessLinx Runtime OperationWriting OPC ValuesIn runtime, values can be manually written to an

Pagina 42 - Copying/Moving TagMaps

Publication 1757-UM002B-EN-P - January 2003ProcessLinx Runtime Operation 4-3Redundant OPC Servers / Fail overProcessLinx supports redundant OPC

Pagina 43 - Multiple TagMap

Publication 1757-UM002B-EN-P - January 20034-4 ProcessLinx Runtime OperationServer StatusYou can view the runtime status of each Pipe’s OPC Ser

Pagina 44 - Testing a ProcessLinx

Publication 1757-UM002B-EN-P - January 2003ProcessLinx Runtime Operation 4-5Verifying OPC TagsIn runtime, you can verify the status of all acti

Pagina 45 - ProcessLinx Runtime Operation

Publication 1757-UM002B-EN-P - January 2003P-3Rockwell Automation Technical SupportRockwell Automation offers support services worldwide, with over 75

Pagina 46 - Writing OPC Values

Publication 1757-UM002B-EN-P - January 20034-6 ProcessLinx Runtime OperationNotes:

Pagina 47 - Fail over

1 Publication 1757-UM002B-EN-P - January 2003 Chapter 5Import/ExportThis chapter provides ProcessLinx TagMap import/export examples. Using the Import/

Pagina 48 - Server Status

Publication 1757-UM002B-EN-P - January 20035-2 Import/ExportWhen you choose Yes, to overwrite the existing Pipe with the import information, Pr

Pagina 49 - OPCShutdown

Publication 1757-UM002B-EN-P - January 2003Import/Export 5-3CSV File FormatsA CSV file is an ASCII Text file that contains fields delimited by

Pagina 50

Publication 1757-UM002B-EN-P - January 20035-4 Import/ExportPipe DeclarationsEach Pipe object in the CSV file starts with BEGIN_PIPE and ends w

Pagina 51 - Import/Export

Publication 1757-UM002B-EN-P - January 2003Import/Export 5-5Group DeclarationsAll Groups in a Pipe are declared between the BEGIN_PIPE and END_

Pagina 52 - 5-2 Import/Export

Publication 1757-UM002B-EN-P - January 20035-6 Import/ExportTagMap DeclarationsAn unlimited number of TagMaps can be defined in each Group. Eac

Pagina 53 - CSV File Formats

Publication 1757-UM002B-EN-P - January 2003Import/Export 5-7Translation Table declarationsTranslation tables are defined at the end of the CSV

Pagina 54 - Pipe Declarations

Publication 1757-UM002B-EN-P - January 20035-8 Import/Export3. In the TagMap dialog box in ProcessLinx click the Read from Export Directory to

Pagina 55 - Group Declarations

1 Publication 1757-UM002B-EN-P - January 2003Chapter 6Error Diagnosis and DebuggingThis chapter explains how to diagnosis errors and debug ProcessLinx

Pagina 56 - TagMap Declarations

Publication 1757-UM002B-EN-P - January 2003P-4ConventionsTerms and Type RepresentationsThe following table summarizes the terms and type representatio

Pagina 57 - Import/Export 5-7

Publication 1757-UM002B-EN-P - January 20036-2 Error Diagnosis and Debugging8.Is ProcessLogix the main OPC Server?• You may need to create a us

Pagina 58 - 5-8 Import/Export

Publication 1757-UM002B-EN-P - January 2003Error Diagnosis and Debugging 6-3Debug OperationsYou can execute simple debug operations during runt

Pagina 59 - Error Diagnosis and Debugging

Publication 1757-UM002B-EN-P - January 20036-4 Error Diagnosis and DebuggingIn runtime mode, ProcessLinx supports the following debug options:T

Pagina 60

1 Publication 1757-UM002B-EN-P - January 2003Chapter 7Using DCOM OPC ServersThis section details how to setup and diagnosis problems with DCOM Servers

Pagina 61 - Debug Operations

Publication 1757-UM002B-EN-P - January 20037-2 Using DCOM OPC Serversunder the Identity tab. Launching User is the default option, so this task

Pagina 62

Publication 1757-UM002B-EN-P - January 2003Using DCOM OPC Servers 7-3• EnableDCOM key. Set to ‘Y’ on BOTH the remote OPC server machine and the

Pagina 63 - Using DCOM OPC Servers

Publication 1757-UM002B-EN-P - January 20037-4 Using DCOM OPC ServersNotes:

Pagina 64

Publication ICCG-5.21- January 2001 PN 955107-82How Are We Doing?Your comments on our technical publications will help us serve you better in the fut

Pagina 65

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Pagina 67 - How Are We Doing?

i Publication 1757-UM002B-EN-P - January 2003Table of ContentsPrefaceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 68 - BUSINESS REPLY MAIL

Publication 1757-UM002B-EN-P - January 2003 2 PN 957726-17Supersedes Publication 1757-UM002A-EN-P - May 2001 Copyright © 2003 Rockwell Automation, Inc

Pagina 69

Publication 1757-UM002B-EN-P - January 2003Table of Contents iiChapter 4ProcessLinx Runtime OperationMonitoring Values . . . . . . . . . . . .

Pagina 70

1 Publication 1757-UM002B-EN-P - January 2003Chapter 1Setup ProceduresInstallationThis chapter contains an overview of the setup procedure and the ste