Publication 1757-UM002B-EN-P - January 2003
ProcessLinx TagMap Configuration 3-3
Name blank or set it to “localHost”.
Included in ProcessLinx 2.0 is an executable that only allows you to
create and/or Import up to 10 Pipes. Configure this setting by
creating/editing a REG_DWORD Registry key value at:
HKLM\SOFTWARE\Rockwell Software\ProcessLinx\Options\MaxPipes
The default is 10 if the Key is not found. If value is set to less than 1 the
default is set to 10 since there should always exist at least 1 Pipe.
Importing more than 10 Pipes and creating more than 10 Pipes has
been tested and in each case a Message Box will prompt you to the
actual limit allowed.