Rockwell-automation 1747-PTxx Getting Started Guide for HHT Manual de usuario Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 77
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
Chapter 3
Creating a Program
3–12
Entering an “Examine if Closed” Instruction
1. Press
[F1]
– INS_INST
. The following display appears:
F1 F2 F3 F4 F5
2.0.0.0.*
BIT TMR/CNT I/O_MSG CPT/MTH
OFL
>
COMPARE
<END>
2. Press [F1]
– BIT
. The following display appears:
F1 F2 F3 F4 F5
2.0.0.0.*
>
] [
( )
]/[
( )
L
OFL
( )
U
<END>
3. Press [F1]
—] [—
. The following display appears:
ENTER BIT ADDR:
ZOOM on XIC
NAME: EXAMINE IF CLOSED
BIT ADDR:
F1 F2 F3 F4 F5
] [
2.0.0.0.*
Note that the HHT
“shifts” for you.
4. At the ENTER
BIT ADDR:
prompt, type the address I:1/0, then [ENTER].
(If you entered the wrong instruction by mistake, just press
[ESC] and try
again.)
5. Press
[F5]
– ACCEPT
. This accepts the address. The following display
appears:
F1 F2 F3 F4 F5
] [
( )
]/[
( ) ( )
>L
OFL
U
2.0.0.0.*
<END>
] [
Vista de pagina 36