Rockwell-automation 1756-Lx_Mx ControlLogix Controller and Memory Boar Manual de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 52
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
42 ControlLogix® Controller and Memory Board
Publication
1756-IN101J-EN-P - November 2004
The following specifications apply to all ControlLogix controllers:
Description: Value:
Operating Temperature IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
0° … 60° C (32 … 140° F)
Storage Temperature IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),
IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),
IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal Shock):
-40° … 85° C (-40 … 185° F)
Relative Humidity IEC 60068-2-30 (Test Db, Un-packaged Non-operating
Damp Heat):
5% … 95% noncondensing
Vibration IEC60068-2-6 (Test Fc, Operating):
2g @ 10-500Hz
Operating Shock IEC60068-2-27 (Test Ea, Unpackaged Shock):
30g
Non-Operating Shock IEC60068-2-27 (Test Ea, Unpackaged Shock):
50g
Emissions CISPR 11:
Group 1, Class A
ESD Immunity IEC 61000-4-2:
6kV contact discharges
8kV air discharges
Radiated RF Immunity IEC 61000-4-3:
10V/m with 1kHz sine-wave 80%AM from 30MHz … 2000MHz
10V/m with 200Hz 50% Pulse 100%AM at 900Mhz
10V/m with 200Hz 50% Pulse 100%AM at 1890Mhz
EFT/B immunity IEC 61000-4-4:
±4kV at 5kHz on power ports
±4kV at 5kHz on communications ports
Surge Transient Immunity IEC 61000-4-5:
±1kV line-line(DM) and ±2kV line-earth(CM) on AC power ports
±2kV line-earth(CM) on communications ports
Conducted RF Immunity IEC 61000-4-6:
10Vrms with 1kHz sine-wave 80%AM from 150kHz … 80MHz
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 51 52

Comentarios a estos manuales