Rockwell-automation 1761-NET-AIC Advanced Interface Converter (AIC+) U Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1761-NET-AIC Advanced Interface Converter (AIC+) U. Rockwell Automation 1761-NET-AIC Advanced Interface Converter (AIC+) User Manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 46
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
AIC+ Advanced
Interface Converter
Catalog Number 1761-NET-AIC
User Manual
Vista de pagina 0
1 2 3 4 5 6 ... 45 46

Indice de contenidos

Pagina 1 - Interface Converter

AIC+ Advanced Interface Converter Catalog Number 1761-NET-AICUser Manual

Pagina 2 - Important User Information

Publication 1761-UM004B-EN-P - June 20066 Product OverviewThe communication-rate selector switch is used to match the communication rate filter

Pagina 3 - Summary of Changes

Publication 1761-UM004B-EN-P - June 2006Product Overview 7Node Address Identification There is no node address associated with the network port

Pagina 4 - 4 Summary of Changes

Publication 1761-UM004B-EN-P - June 20068 Product Overview

Pagina 5 - Table of Contents

9 Publication 1761-UM004B-EN-P - June 2006Chapter 2Installation and WiringCompliance to European Union DirectivesIf this product has the CE mark it is

Pagina 6 - Appendix A

Publication 1761-UM004B-EN-P - June 200610 Installation and WiringSafety ConsiderationsThis equipment is suitable for use in Class I, Division

Pagina 7 - Purpose of This Manual

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 11Mount the AIC+ Advanced Interface ConverterThe AIC+ interface converter can b

Pagina 8 - Conventions Used in This

Publication 1761-UM004B-EN-P - June 200612 Installation and WiringMount to a Panel Follow these instructions to mount your AIC+ interface conve

Pagina 9 - Product Overview

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 13Wire the AIC+ Advanced Interface ConverterThis section provides power supply

Pagina 10 - Operation Modes

Publication 1761-UM004B-EN-P - June 200614 Installation and WiringWire to the Network PortsUse these instructions for wiring Belden cable.Attac

Pagina 11 - Node Address Identification

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 15The table below shows connections for Belden #3106A. The table below shows co

Pagina 12 - 8 Product Overview

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Pagina 13 - Installation and Wiring

Publication 1761-UM004B-EN-P - June 200616 Installation and WiringCable ChoicesThis section provides information that will help you determine t

Pagina 14 - Safety Considerations

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 171761-CBL-AS03 and 1761-CBL-AS09 Cable1761-CBL-AM00 and 1761-CBL-HM02 Cable 17

Pagina 15 - Mount the AIC+ Advanced

Publication 1761-UM004B-EN-P - June 200618 Installation and Wiring1761-CBL-AP00 and 1761-CBL-PM02 Cable 1761-CBL-AP00 and 1761-CBL-PM02 CableCa

Pagina 16 - Mount to a Panel

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 19User-supplied CableRecommended User-supplied ComponentsThese components can b

Pagina 17 - Wire the AIC+ Advanced

Publication 1761-UM004B-EN-P - June 200620 Installation and Wiring PortsPin # DB-9 RS-232 RS-232 (8-pin mini-DIN) Communication Port(1) (1761-

Pagina 18 - IMPORTANT

21 Publication 1761-UM004B-EN-P - June 2006Chapter 3Network Connections Network DiagramsThis chapter provides various network connections. The item nu

Pagina 19 - 1219 m (4000 ft) Maximum

Publication 1761-UM004B-EN-P - June 200622 Network ConnectionsComponents Replaced by the AIC+ Interface Converter The AIC+ interface converter

Pagina 20 - Cable Choices

Publication 1761-UM004B-EN-P - June 2006Network Connections 23DH-485 Network with SLC 5/03 and SLC 5/04 Processors and a PC DH-485 Network with

Pagina 21 - 1761-CBL-HM02

Publication 1761-UM004B-EN-P - June 200624 Network ConnectionsDH-485 Network with a MicroLogix 1000 Controller DH-485 Network with a MicroLogix

Pagina 22 - 1761-CBL-AP00

Publication 1761-UM004B-EN-P - June 2006Network Connections 25Networked Operator-interface Device and MicroLogix Controller Networked Operator-

Pagina 23 - User-supplied Components

3 Publication 1761-UM004B-EN-P - June 2006Summary of ChangesThe information below summarizes the changes to this manual since the last printing.To hel

Pagina 24

Publication 1761-UM004B-EN-P - June 200626 Network ConnectionsNetworks Using Ganged Converters Networks Using Ganged Converters1761-CBL-AS09 or

Pagina 25 - Network Connections

Publication 1761-UM004B-EN-P - June 2006Network Connections 27Network Extended to 2438 m (8000 ft) Network Extended to 2438 m (8000 ft)24V dc(U

Pagina 26 - Link Coupler

Publication 1761-UM004B-EN-P - June 200628 Network ConnectionsDF1 Master-slave Network with Modem DF1 Master-slave Network with ModemUse this d

Pagina 27 - DH-485 Network

Publication 1761-UM004B-EN-P - June 2006Network Connections 29Avoid Incorrect Connections Incorrect ConnectionsIMPORTANTIn this configuration,

Pagina 28 - Typical Three-node Network

Publication 1761-UM004B-EN-P - June 200630 Network Connections

Pagina 29 - 1747-CP3 or

31 Publication 1761-UM004B-EN-P - June 2006Chapter 4Interpret the LED IndicatorsDiagnostics LED Indicators and Selector SwitchLED Indicator StatusLED

Pagina 30 - 1761-CBL-HM02 Cable

Publication 1761-UM004B-EN-P - June 200632 Interpret the LED Indicators

Pagina 31 - 1761-CBL-AM00 or

33 Publication 1761-UM004B-EN-P - June 2006Appendix ASpecifications and DimensionsGeneral SpecificationsAIC+ Advanced Interface Converter - 1761-NET-A

Pagina 32 - 28 Network Connections

Publication 1761-UM004B-EN-P - June 200634 Specifications and DimensionsIsolation Between All Ports and Power Supply TerminalsHardware Handshak

Pagina 33 - 1761-CBL-AS09 or

Publication 1761-UM004B-EN-P - June 2006Specifications and Dimensions 35Auto Transmit Delay (turnaround time) per Communication Rate Auto-trans

Pagina 34 - 30 Network Connections

Publication 1761-UM004B-EN-P - June 20064 Summary of Changes

Pagina 35 - Interpret the LED Indicators

Publication 1761-UM004B-EN-P - June 200636 Specifications and DimensionsMounting Template 52.07 mm (2.05 in.)118 mm (4.64 in.)107 mm (4.20 in.)

Pagina 36

Publication 1761-UM004B-EN-P - June 2006IndexAAIC+ Advanced Interface Convertercompatibility with other devices 6connect to a network 21dimensions 36L

Pagina 37 - Specifications and Dimensions

Publication 1761-UM004B-EN-P - June 20062 Index

Pagina 38 - (turnaround time) is zero

Publication CIG-CO521C-EN-P- May 2003 PNXXXXXX-XX957782-91How Are We Doing?Your comments on our technical publications will help us serve you better

Pagina 39

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Pagina 41

Publication 1761-UM004B-EN-P - June 2006 7Supersedes Publication 1761-6.4 - April 1998 Copyright © 2006 Rockwell Automation, Inc. All rights reserved.

Pagina 42 - 2 Index

i Publication 1761-UM004B-EN-P - June 2006Table of ContentsPrefaceWho Should Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . 3Purpose

Pagina 43 - How Are We Doing?

Publication 1761-UM004B-EN-P - June 2006ii Table of ContentsAppendix ASpecifications and DimensionsGeneral Specifications . . . . . . . . . . .

Pagina 44 - BUSINESS REPLY MAIL

3 Publication 1761-UM004B-EN-P - June 2006PrefaceRead this preface to familiarize yourself with the rest of the manual. This preface covers the follow

Pagina 45

Publication 1761-UM004B-EN-P - June 20064 PrefaceAdditional ResourcesThe following documents contain additional information regarding Rockwell

Pagina 46 - Rockwell Automation

5 Publication 1761-UM004B-EN-P - June 2006Chapter 1Product OverviewDescriptionThe AIC+ advanced interface converter provides a communication link betw

Comentarios a estos manuales

Sin comentarios