Rockwell-automation 1769-IF4FXOF2F Compact Combination Fast Analog I/O Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20 Compact Combination Fast Analog I/O Module
Publication 1769-IN081A-EN-P - February 2007
The bits are defined as follows:
SGN = Sign bit in 2’s complement format.
Real Time Sample Value = Provides the ability to configure the Real Time
Sample Rate.
ETS = Enable Time Stamping.
EC = Enable Channel.
EA = Enable Alarm.
AL = Alarm Latch.
EI = Enable Input Process Alarm Interrupt.
Input Filter Sel ChIx = Input Channel Filter Setting.
Inpt Dta Fm ChIx = Input Data Format Select.
Inpt Tp/Rnge Sel ChIx = Input Type/Range Select.
Word 22 SGN Process Alarm High Data Value Channel 3 0
Word 23 SGN Process Alarm Low Data Value Channel 3 0
Word 24 SGN Alarm Dead Band Value Channel 3 0
Word 25 Reserved
Word 26 EC Reserved EHI ELI LC ER FM PM 0 PFE
Word 27 Reserved Outpt Fm ChI0 Reserved Outpt Tp/Rnge Sel
ChI0
Word 28 SGN Fault Value Channel 0 0 0
Word 29 SGN Program (Idle) Value Channel 0 0 0
Word 30 SGN Clamp High Data Value Channel 0 0 0
Word 31 SGN Clamp Low Data Value Channel 0 0 0
Word 32 SGN Ramp Rate Channel 0 0 0
Word 33 Reserved
Word 34 EC Reserved EHI ELI LC ER FM PM 0 PFE
Word 35 Reserved Outpt Fm ChI1 Reserved Outpt Tp/Rnge Sel
ChI1
Word 36 SGN Fault Value Channel 1 0 0
Word 37 SGN Program (Idle) Value Channel 1 0 0
Word 38 SGN Clamp High Data Value Channel 1 0 0
Word 39 SGN Clamp Low Data Value Channel 1 0 0
Word 40 SGN Ramp Rate Channel 1 0 0
Word 41 Reserved