Rockwell-automation 1797-OE8 FLEX Ex Analog Modules User Manual Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 1797-OE8 FLEX Ex Analog Modules User Manual. Rockwell Automation 1797-OE8 FLEX Ex Analog Modules User Manual User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - FLEX Ex Analog

FLEX Ex Analog Modules1797-IE8, -IE8NF, and -OE8User Manual

Pagina 2 - Important User Information

Publication 1797-6.5.1 - May 2005Preface 2For Additional InformationFor additional information on FLEX Ex systems and modules, refer to the fol

Pagina 3 - Summary of Changes

Publication 1797-6.5.1 - May 20052 KKeyswitchusing on the terminal base unit 3-9LLatch Retry Mode1797-OE8 module 2-8Local Fault Mode1797-OE8 mo

Pagina 4 - Summary of Changes ii

Publication CIG-CO521C-EN-P- May 2003 PN957831-49957782-91How Are We Doing?Your comments on our technical publications will help us serve you better

Pagina 5 - Table of Contents

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Pagina 7 - iii

Publication 1797-6.5.1 - May 2005 4 PN 957831-49Supersedes Publication 1797-6.5.1 - April 1999 Copyright © 2005 Rockwell Automation, Inc. All rights r

Pagina 8 - iv

1 Publication 1797-6.5.1 - May 2005Chapter 1About the FLEX Ex Analog ModulesWhat this Chapter ContainsRead this chapter to familiarize yourself with t

Pagina 9 - ™ analog modules with the

Publication 1797-6.5.1 - May 20051-2 About the FLEX Ex Analog ModulesHow FLEX Ex Analog Modules Communicate with Programmable ControllersFLEX E

Pagina 10 - For Additional Information

Publication 1797-6.5.1 - May 2005About the FLEX Ex Analog Modules 1-3Physical Features of Your Analog I/O ModuleThe module label identifies the

Pagina 11 - I/O Modules Do

Publication 1797-6.5.1 - May 20051-4 About the FLEX Ex Analog ModulesData Format Alarm ExampleIn this example, the normal active data range is

Pagina 12 - Controllers

Publication 1797-6.5.1 - May 2005About the FLEX Ex Analog Modules 1-5Remote Fault AlarmThe Remote Fault Alarm is primarily intended for use wit

Pagina 13 - 1797-IE8 and -IE8NF

Publication 1797-6.5.1 - May 20051-6 About the FLEX Ex Analog ModulesProgramming the Remote Fault AlarmFor the Remote Fault alarm, you must pro

Pagina 14 - Underrange Alarm

1 Publication 1797-6.5.1 - May 2005Chapter 2Understanding Configurable FLEX ExAnalog Module FeaturesWhat this Chapter ContainsRead this chapter to fam

Pagina 15 - Remote Fault Alarm

Publication 1797-6.5.1 - May 20052-2 Understanding Configurable FLEX Ex Analog Module FeaturesYou must use the I/O configuration portion of you

Pagina 16 - Chapter Summary

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-3Remote Transmitter Error Up or DownA second featu

Pagina 17 - Analog Module Features

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Pagina 18 - Features

Publication 1797-6.5.1 - May 20052-4 Understanding Configurable FLEX Ex Analog Module FeaturesData FormatYou must choose a module data format i

Pagina 19 - Input Filter Cutoff

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-55 4-20mA as %0.16% of 4-20mA2-22mA -1250 - +11250

Pagina 20 - Data Format

Publication 1797-6.5.1 - May 20052-6 Understanding Configurable FLEX Ex Analog Module FeaturesData Formats and Error RangesThe graphic below sh

Pagina 21

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-7Selecting a 1797-OE8 FLEX Ex Analog Output Module

Pagina 22 - Data Formats and Error Ranges

Publication 1797-6.5.1 - May 20052-8 Understanding Configurable FLEX Ex Analog Module FeaturesLatch Retry ModeLatch Mode determines channel ope

Pagina 23 - Operating Features

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-9Analog Fault StateThe Analog Fault State feature

Pagina 24 - Analog Digital State

Publication 1797-6.5.1 - May 20052-10 Understanding Configurable FLEX Ex Analog Module FeaturesData FormatYou must choose a module data format

Pagina 25 - Digital Fault State

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-11Table 2.4 1797-OE8 Data FormatsData FormatFormat

Pagina 26 - 11=data out of range

Publication 1797-6.5.1 - May 20052-12 Understanding Configurable FLEX Ex Analog Module FeaturesFault AlarmFault Alarm selects whether the chann

Pagina 27

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-13Understanding Image Table Mapping and Bit/Word D

Pagina 28 - Fault Alarm

i Publication 1797-6.5.1 - May 2005Summary of ChangesThe information below summarizes the changes to this manual since the last printing.To help you f

Pagina 29 - Descriptions

Publication 1797-6.5.1 - May 20052-14 Understanding Configurable FLEX Ex Analog Module FeaturesAnalog Input Modules (1797-IE8 and -IE8NF) Image

Pagina 30

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-15Bit/Word Description for the Analog Input Module

Pagina 31 - (1797-IE8 and -IE8NF)

Publication 1797-6.5.1 - May 20052-16 Understanding Configurable FLEX Ex Analog Module FeaturesTable 2.11 Data Format - Write Words 0 and 1Tabl

Pagina 32 - Res Flg = Response Flag

Publication 1797-6.5.1 - May 2005Understanding Configurable FLEX Ex Analog Module Features 2-17Bit/Word Descriptions for the Analog Output Modu

Pagina 33 - (1797-OE8)

Publication 1797-6.5.1 - May 20052-18 Understanding Configurable FLEX Ex Analog Module FeaturesTable 2.15 Data Format ControlChapter SummaryIn

Pagina 34

1 Publication 1797-6.5.1 - May 2005Chapter 3How to Install Your FLEX Ex Analog ModulesWhat this Chapter ContainsRead this chapter to install the input

Pagina 35 - Analog Module

Publication 1797-6.5.1 - May 20053-2 How to Install Your FLEX Ex Analog ModulesCompliance to EuropeanUnion DirectivesIf these products have the

Pagina 36 - Union Directives

Publication 1797-6.5.1 - May 2005How to Install Your FLEX Ex Analog Modules 3-3Installation in Zone 1These modules must not be exposed to the e

Pagina 37 - Electrostatic Charge

Publication 1797-6.5.1 - May 20053-4 How to Install Your FLEX Ex Analog ModulesRemoval and InsertionUnder PowerInstalling the ModuleInstallatio

Pagina 38 - Installing the Module

Publication 1797-6.5.1 - May 2005How to Install Your FLEX Ex Analog Modules 3-5Mounting on a DIN Rail1. Remove the cover plug in the male conne

Pagina 39 - Mounting on a DIN Rail

Publication 1797-6.5.1 - May 2005Summary of Changes iiNotes:

Pagina 40

Publication 1797-6.5.1 - May 20053-6 How to Install Your FLEX Ex Analog Modules5. Rotate the terminal base onto the DIN rail with the top of th

Pagina 41 - Panel/Wall Mounting

Publication 1797-6.5.1 - May 2005How to Install Your FLEX Ex Analog Modules 3-76. For specific wiring information, refer to the installation in

Pagina 42 - IMPORTANT

Publication 1797-6.5.1 - May 20053-8 How to Install Your FLEX Ex Analog ModulesTo install the mounting plate on a wall or panel:1. Lay out the

Pagina 43 - Label under here

Publication 1797-6.5.1 - May 2005How to Install Your FLEX Ex Analog Modules 3-96. Position the terminal base unit up against the adapter and pu

Pagina 44 - Wiring the Terminal Base

Publication 1797-6.5.1 - May 20053-10 How to Install Your FLEX Ex Analog Modules3. Make sure the pins on the bottom of the module are straight

Pagina 45 - FLEX Ex I/O Analog

Publication 1797-6.5.1 - May 2005How to Install Your FLEX Ex Analog Modules 3-11Connecting Wiring to theFLEX Ex I/O Analog ModulesInputs/Output

Pagina 46 - ATTENTION

Publication 1797-6.5.1 - May 20053-12 How to Install Your FLEX Ex Analog ModulesFor Two-Wire Transmitter Devices1. Connect the individual input

Pagina 47

Publication 1797-6.5.1 - May 2005How to Install Your FLEX Ex Analog Modules 3-13Connections for the 1797-OE8 Module1. Connect the individual ou

Pagina 48 - Grounding the Module

Publication 1797-6.5.1 - May 20053-14 How to Install Your FLEX Ex Analog ModulesTable 3.3 Wiring connections for the 1797-OE8 ModuleGrounding t

Pagina 49 - ControlNet Network

1797-6.5.1 - MayChapter 4Input, Output, and Configuration Filesfor the Analog I/O Modules on the ControlNet NetworkWhat this Chapter ContainsRead this

Pagina 50 - About the ControlNet Ex

i Publication 1797-6.5.1 - May 2005Table of ContentsPrefaceWhy Read This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 51 - FLEX Ex Backplane

Publication 1797-6.5.1 - May 20054-2 Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet NetworkUsing Programmi

Pagina 52 - I/O Structure

Publication 1797-6.5.1 - May 2005Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet Network 4-3Communication O

Pagina 53 - Adapter Status Word

Publication 1797-6.5.1 - May 20054-4 Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet NetworkUnscheduled mes

Pagina 54 - Device Actions

Publication 1797-6.5.1 - May 2005Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet Network 4-5Adapter Status

Pagina 55 - Idle State Behavior

Publication 1797-6.5.1 - May 20054-6 Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet NetworkPossible causes

Pagina 56

Publication 1797-6.5.1 - May 2005Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet Network 4-7Communication F

Pagina 57 - Calibrating Your Module

Publication 1797-6.5.1 - May 20054-8 Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet NetworkInput Data Beha

Pagina 58 - Command Words

1 Publication 1797-6.5.1 - May 2005Chapter 5Calibrating Your ModuleWhat This Chapter ContainsUse this chapter to calibrate the FLEX Ex analog I/O modu

Pagina 59

Publication 1797-6.5.1 - May 20055-2 Calibrating Your ModuleUse one of the following general methods to calibrate your module:• Use intrinsical

Pagina 60

Publication 1797-6.5.1 - May 2005Calibrating Your Module 5-3Typical MODULE Calibration Command WordThe controller sends a MODULE calibration co

Pagina 61 - General MODULE Response Word

Publication 1797-6.5.1 - May 2005 iiUnderstanding Image Table Mapping and Bit/Word Descriptions 2-13Bit Descriptions . . . . . . . . . . . . .

Pagina 62 - Input Modules

Publication 1797-6.5.1 - May 20055-4 Calibrating Your ModuleFor example, based on the table below, command 4 0 0 asks for zeroing the min and m

Pagina 63

Publication 1797-6.5.1 - May 2005Calibrating Your Module 5-5General MODULE Response WordOnce the I/O module echoes the command and data it will

Pagina 64 - Output Modules

Publication 1797-6.5.1 - May 20055-6 Calibrating Your ModuleCalibrating the Input ModulesTo calibrate the 1797-IE8 or -IE8NF module use the fol

Pagina 65

Publication 1797-6.5.1 - May 2005Calibrating Your Module 5-79. Await an echo message from the module announcing that it has performed Max Scale

Pagina 66

Publication 1797-6.5.1 - May 20055-8 Calibrating Your ModuleCalibrating the Output ModulesTo calibrate the 1797-OE8 module use the following ge

Pagina 67 - Evaluate the Application

Publication 1797-6.5.1 - May 2005Calibrating Your Module 5-97. Record the value indicated by the channel(s) precision current meter into the ap

Pagina 68 - Classification

Publication 1797-6.5.1 - May 20055-10 Calibrating Your ModuleThe following table shows the calibration MODULE command definitions.Chapter Summa

Pagina 69 - Match Field Devices

1 Publication 1797-6.5.1 - May 2005Chapter 6Applying FLEX Ex Analog I/O ModulesWhat this Chapter ContainsRead this chapter to learn how to use entity

Pagina 70

Publication 1797-6.5.1 - May 20056-2 Applying FLEX Ex Analog I/O ModulesDefine the Area ClassificationBefore you can determine what components

Pagina 71

Publication 1797-6.5.1 - May 2005Applying FLEX Ex Analog I/O Modules 6-3Select Protection Method(s)Although the FLEX Ex system primarily uses t

Pagina 72

Publication 1797-6.5.1 - May 2005 iiiChapter 4Input, Output, and Configuration Files for the Analog I/O Modules on the ControlNet NetworkWhat t

Pagina 73 - Distribution

Publication 1797-6.5.1 - May 20056-4 Applying FLEX Ex Analog I/O Modules1797-IE8 and -IE8NF Functional and IS ParametersThe figure below provid

Pagina 74 - Hazardous Area

Publication 1797-6.5.1 - May 2005Applying FLEX Ex Analog I/O Modules 6-5The loop must function properly under maximum signal current conditions

Pagina 75

Publication 1797-6.5.1 - May 20056-6 Applying FLEX Ex Analog I/O ModulesIntrinsic Safety Entity VerificationNext we must determine if the press

Pagina 76

Publication 1797-6.5.1 - May 2005Applying FLEX Ex Analog I/O Modules 6-7I/OThe input and output modules comply fully to and provide simple enti

Pagina 77 - Analog I/O Modules

Publication 1797-6.5.1 - May 20056-8 Applying FLEX Ex Analog I/O ModulesAssign the next module to another output as before. When all four power

Pagina 78

Publication 1797-6.5.1 - May 2005Applying FLEX Ex Analog I/O Modules 6-9Power Supply ConsiderationsWhen applying power, consider the certain ch

Pagina 79

Publication 1797-6.5.1 - May 20056-10 Applying FLEX Ex Analog I/O ModulesNotes:

Pagina 80

1 Publication 1797-6.5.1 - May 2005Chapter 7Troubleshooting the FLEX ExAnalog I/O ModulesWhat this Chapter ContainsRead this chapter to troubleshoot y

Pagina 81 - Specifications

Publication 1797-6.5.1 - May 20057-2 Troubleshooting the FLEX Ex Analog I/O Modules1797-OE8 ModuleThe 1797-OE8 module has one power that is on

Pagina 82 - Class I Division 1 Hazardous

Publication 1797-6.5.1 - May 2005Troubleshooting the FLEX Ex Analog I/O Modules 7-3Notes:

Pagina 83 - Specifications A-3

Publication 1797-6.5.1 - May 2005 ivChapter 7Troubleshooting the FLEX ExAnalog I/O ModulesWhat this Chapter Contains. . . . . . . . . . . . . .

Pagina 84 - Wiring Methods

Publication 1797-6.5.1 - May 20057-4 Troubleshooting the FLEX Ex Analog I/O Modules

Pagina 85

1 Publication 1797-6.5.1 - May 2005Appendix ASpecifications1797-IE8 and -IE8NF Input ModulesSpecificationsNumber of Inputs 8 single-ended, non-isolate

Pagina 86 - A-6 Specifications

Publication 1797-6.5.1 - May 2005A-2 SpecificationsPower Dissipation 5.2WThermal Dissipation 17.75 BTU/hrModule Location Cat. No. 1797-TB3 or -

Pagina 87

Publication 1797-6.5.1 - May 2005Specifications A-31797-IE8 and -IE8NF CE, CENELEC I/O Entity ParametersMeasurement input (sig to -) for ch 0 t

Pagina 88 - Shield Connection Only

Publication 1797-6.5.1 - May 2005A-4 Specifications1797-IE8 and -IE8NF UL, C-UL I/O Entity ParametersIf this product has the UL/C-UL mark, it h

Pagina 89 - Specifications A-9

Publication 1797-6.5.1 - May 2005Specifications A-5IMPORTANTA terminal base may or may not have an I/O module installed. 1797- IE8Allen-Bradl

Pagina 90 - 1797-OE8 Output Module

Publication 1797-6.5.1 - May 2005A-6 SpecificationsTable 2 The entity concept allows interconnection of intrinsically safe apparatus with asso

Pagina 91

Publication 1797-6.5.1 - May 2005Specifications A-71797-IE8 and -IE8NF FM I/O Entity ParametersIf this product has the FM mark, it has been des

Pagina 92

Publication 1797-6.5.1 - May 2005A-8 SpecificationsIMPORTANTA terminal base may or may not have an I/O module installed. 1797- IE8Allen-Bradl

Pagina 93

Publication 1797-6.5.1 - May 2005Specifications A-9Table 2 The entity concept allows interconnection of intrinsically safe apparatus with asso

Pagina 94 - A-14 Specifications

1 Publication 1797-6.5.1 - May 2005PrefaceWhy Read This ManualThis manual shows you how to use your FLEX Ex™ analog modules with the ControlNet Ex™ pr

Pagina 95

Publication 1797-6.5.1 - May 2005A-10 Specifications1797-OE8 Output ModuleSpecificationsNumber of Outputs 8 single-ended, non-isolatedIS Output

Pagina 96

Publication 1797-6.5.1 - May 2005Specifications A-111797-OE8 CENELEC I/O Entity ParametersSignal output (+ to -) for ch 0 to ch 7 (terminals: 0

Pagina 97 - Specifications A-17

Publication 1797-6.5.1 - May 2005A-12 Specifications1797-OE8 UL, C-UL I/O Entity ParametersIf this product has the UL/C-UL mark, it has been de

Pagina 98 - A-18 Specifications

Publication 1797-6.5.1 - May 2005Specifications A-13IMPORTANTA terminal base may or may not have an I/O module installed. 1797- OE8Allen-Brad

Pagina 99

Publication 1797-6.5.1 - May 2005A-14 SpecificationsTable 2 The entity concept allows interconnection of intrinsically safe apparatus with ass

Pagina 100 - 2

Publication 1797-6.5.1 - May 2005Specifications A-151797-OE8 FM I/O Entity ParametersIf this product has the FM mark, it has been designed, eva

Pagina 101 - How Are We Doing?

Publication 1797-6.5.1 - May 2005A-16 SpecificationsIMPORTANTA terminal base may or may not have an I/O module installed. 1797- IE8Allen-Brad

Pagina 102 - BUSINESS REPLY MAIL

Publication 1797-6.5.1 - May 2005Specifications A-17Table 2 The entity concept allows interconnection of intrinsically safe apparatus with ass

Pagina 103

Publication 1797-6.5.1 - May 2005A-18 SpecificationsNotes:

Pagina 104 - Rockwell Automation

Publication 1797-6.5.1 - May 2005IndexAAlarms1797-IE8 module 1-3local fault 1-3, 1-6overrange 1-3, 1-4programming remote fault 1-6remote fault 1-3, 1-