Power Wiring Requirements
Wire must be copper with 75 °C (167 °F) minimum rating. The phase connections of the main
AC power are arbitrary and earth-ground connection is required for safe and proper operation.
Drive Cat. No. Description
Terminals Recommended
Wire Size
mm
2
(AWG)
Strip
Length
mm (in.)
Torque Value
N•m (lb•in)
Pin Signal
2071-AP0
2071-AP1
2071-AP2
2071-AP4
Input and control
power
IPD-L1
IPD-L2
IPD-L1C
IPD-L2C
L1
L2
L1C
L2C
2.5 (14) 8 (0.3)
N/A
Ground screw Ground 1.25 (11)
2071-AP8
IPD-L1
IPD-L2
(IPD-L3)
IPD-L1C
IPD-L2C
L1
L2
(L3)
L1C
L2C
N/A
Ground screw Ground 1.25 (11)
2071-A10
2071-A15
IPD-L1
IPD-L2
IPD-L3
IPD-L1C
IPD-L2C
L1
L2
L3
L1C
L2C
N/A
Ground screw Ground 1.25 (11)
2071-xxx Motor power
MP-U
MP-V
MP-W
U
V
W
N/A
Ground screw GND 1.25 (11)
2071-xxx Shunt resistor
(1)
(1) Use only for shunt resistor connection.
BC-B1
BC-B2
B1
B2
N/A
ATTENTION: To avoid personal injury and equipment damage, be sure of the following:
Installation complies with specifications regarding wire types, conductor sizes, branch circuit
protection, and disconnect devices. The National Electrical Code (NEC) and local codes outline
provisions for safely installing electrical equipment.
Motor power connectors are used only for connection purposes. Do not use motor power
connector to turn the unit on and off.
Shielded power cables are grounded to prevent potentially high voltages on the shield.