Installation Instructions
Optional
Communications
Module
L2L1T3T2T1 L3
INPUTOUTPUT
USE 75 C
COPPER WIRE
ONLY
TORQUE
52 IN-LB
(6 N-M)
BR2
PS+
PS–
BR1 DC+ DC–
USE 75 C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M)
22-10
AWG
5.3 IN-LB
(0.6 N-M)
WIRE STRIP
2
0V
0V
DC–DC+
3
Current Transducer, Power Interface and Power Supply Board
Replacement - Frame 6
1
L1 L2 L3
O
I
=
A. Remove front covers.
B. Disconnect cables from cassette.
C. Remove the plastic shield by taking out the screws.
D. Remove the six screws securing the HIM Support
Plate. Disconnect cables.
E. Remove HIM Support Plate and set aside.
F. Remove the junction box on the bottom of the drive by
taking out the four screws.
G. Remove the left-side enclosure panel by taking out the
appropriate screws.
HIM Support Plate
Plastic Shield
Left-Side
Enclosure Panel
Drive Front
Precharge Board
HIM Support Plate
Vista de pagina 0
1 2

Indice de contenidos

Pagina 1 - Replacement - Frame 6

Installation InstructionsOptionalCommunicationsModuleL2L1T3T2T1 L3INPUTOUTPUTUSE 75 CCOPPER WIREONLYTORQUE52 IN-LB(6 N-M)BR2PS+PS–BR1 DC+ DC–USE 75 C

Pagina 2

2H. Locate components to be replaced.Power Interface Board ReplacementA. Locate the Power Interface Board.B. Label and remove the wires/cables from th

Comentarios a estos manuales