Installation InstructionsPowerFlex® DC Drive - Frame C AC Current Transducers What This Kit Includes• Two AC Current Transducers (with signal wires)•
10 PowerFlex® DC Drive - Frame C AC Current Transducers 11. Remove the upper screw that secures each of the CTs to the U and W phase power terminals.
PowerFlex® DC Drive - Frame C AC Current Transducers 11 – For Non-Regenerative drives only, remove the bolt and washers that secure the U and W phase
Publication 20P-IN027A-EN-P - March 2009Copyright © 2009 Rockwell Automation. All rights reserved. Printed in USA.www.rockwellautomation.comAmericas:
2 PowerFlex® DC Drive - Frame C AC Current Transducers Step 1: Remove Power from the Drive1. Remove and lock-out all incoming power to the drive. !ATT
PowerFlex® DC Drive - Frame C AC Current Transducers 3 Step 2: Remove the Protective Covers1. Disconnect the DPI cable from the HIM assembly (if prese
4 PowerFlex® DC Drive - Frame C AC Current Transducers 4. Disconnect the HIM Communication cable from the connector on the upper right corner of the C
PowerFlex® DC Drive - Frame C AC Current Transducers 5 Step 3: Remove the Existing AC Current Transducers1. Remove the screws that secure the ground w
6 PowerFlex® DC Drive - Frame C AC Current Transducers 3. Remove the two screws and washers that secure the bottom of the Power Supply Filter circuit
PowerFlex® DC Drive - Frame C AC Current Transducers 7 5. Loosen the two captive screws at the top of the Control EMI shield and partially lower the s
8 PowerFlex® DC Drive - Frame C AC Current Transducers 7. Remove the two screws and washers that secure the top of the Power Supply Filter board to th
PowerFlex® DC Drive - Frame C AC Current Transducers 9 9. Remove the lower screw that secures the right side AC Current Transducer to the W phase powe