PowerFlex® DC Drive - Frame C AC Current Transducers 5
Step 3: Remove the
Existing AC Current
Transducers
1. Remove the screws that secure the ground wires to the PE terminal
(from the Transient Noise Filter board) and U phase power terminal
(from the Pulse Transformer board) and remove the wires.
2. Remove the lower screw that secures the left side AC Current
Transducer to the U phase terminal.
=
Transient Noise Filter board
Remove ground wirePE ground stud Remove screw and wire
Remove screw