Rockwell-automation 20P PowerFlex DC Drive - Frame C Armature Circuit Manual de usuario

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 20P PowerFlex DC Drive - Frame C Armature Circuit . Rockwell Automation 20P PowerFlex DC Drive - Frame C Armature Circuit Fuse Replacement User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Installation Instructions
PowerFlex
®
DC Drive - Frame C Armature
Circuit Fuse Replacement
What This Kit Includes
One square body, high speed fuse (non-regenerative drives)
Two square body, high speed fuses (regenerative drives)
Static strap
Tools That You Need
Phillips
®
screwdrivers
Flathead screwdriver
17mm open ended wrench
Phillips
®
is a registered trademark of Phillips Screw Company.
What You Need to Do
To install the Armature circuit fuse(s):
Step 1: Remove power from the drive
Step 2: Remove the protective covers
Step 3: Remove the existing fuse(s)
Step 4: Install the new fuse(s)
Step 5: Replace the protective covers
!
ATTENTION: Only qualified personnel familiar with DC
drives and associated machinery should plan or implement the
installation, start-up and subsequent maintenance of the system.
Failure to comply may result in personal injury and/or equipment
damage.
!
ATTENTION: To avoid an electric shock hazard, ensure that
all power to the drive has been removed before performing the
following.
!
ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - Circuit Fuse Replacement

Installation InstructionsPowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement What This Kit Includes• One square body, high speed fuse (no

Pagina 2 - Protective Covers

2 PowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement Step 1: Remove Power from the Drive1. Remove and lock-out all incoming power to the

Pagina 3

PowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement 3 3. Loosen, but do not remove, the screws that secure the top cover to the drive, the

Pagina 4 - Existing Armature Circuit

4 PowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement Step 3: Remove the Existing Armature Circuit Fuse(s)You must remove the Transient No

Pagina 5 - Loosen screws

PowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement 5 3. Loosen the two captive screws at the top of the Control EMI shield and partially

Pagina 6 - Remove wire leads

6 PowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement 5. If replacing the V Phase Armature circuit fuse(s), remove the two screws that sec

Pagina 7 - Remove bolts

PowerFlex® DC Drive - Frame C Armature Circuit Fuse Replacement 7 8. Remove the two screws that secure the switch to the fuse and remove the switch. R

Pagina 8 - Step 5: Replace the

Publication 20P-IN043A-EN-P - March 2009Copyright © 2008 Rockwell Automation. All rights reserved. Printed in USA.www.rockwellautomation.comAmericas: