Rockwell-automation 20P PowerFlex DC Drive - Frame D Field SCR Module Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
Publication 20P-IN055A-EN-P
Important: Mark all connections and wires before removal to avoid
incorrect wiring during reassembly.
2. Disconnect the cables from connector XFCD and X3 on the field board (see
Figure 2
below for location).
3. Remove the eleven hexalobular screws that secure the field board to the
control EMI shield and remove the board.
Figure 2 Field Circuit Board Layout
XFCD
X3
1
TA_1
PFC-XX
R1R4
C4C7
Note: Field board for 70A field supply shown.
T25
Tightening torque:
2.5…4.0 N•m
(22…35 lb•in)
Tightening torque:
1.0…1.2 N•m
(9…10.5 lb•in)
T25
Vista de pagina 4