Packing Data
PK
   
This document describes how to install a Dataliner DL20 display in a panel or
enclosure and connect power.
European Union Directive Compliance
wiring and safety guidelines
enclosures
required tools
mounting dimensions
clearances
installing the DL20 display in a panel
connecting AC power
For more information on the Dataliner DL20 display, refer to the Dataliner DL20
User Manual (Publication 2706-814).
Installation Instructions
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - Installation Instructions

Packing DataPK   This document describes how to install a Dataliner DL20 display in a panel orenclosure and connect power.•

Pagina 2

Dataliner DL20 Message Display10EMI Power-Line Filters (EU Installations Only)DL20 displays intended for use in the European Union require a power-li

Pagina 3

Dataliner DL20 Message Display 11Connecting AC PowerThe table below shows the electrical ratings for the Dataliner DL20 display.Type of Display Suppl

Pagina 4 - • small slotted screwdriver

Dataliner DL20 Message Display12• Output leads from the power-line filter to the Dataliner must be 10 cm (4 in.) orless.• Both Dataliner and power-li

Pagina 5 - Mounting the DL20

Dataliner DL20 Message Display 13Wiring DiagramThe following diagram shows how to connect the power-line filter forinstallations within the European

Pagina 6 - Mounting Dimensions

Dataliner DL20 Message Display14AC Power ConnectionsConnection120/240V ac, 3 WireU.S. Color Code120/240V ac, 3 WireEuropean Harmonized Color CodeL1

Pagina 7 - Four-Line DL20 Dimensions

Dataliner DL20 Message Display 15Notes:

Pagina 8 - Clearances

Worldwide representation.Argentina • Australia • Austria • Bahrain • Belgium • Brazil • Bulgaria • Canada • Chile • China, PRC •Colombia • Costa Rica

Pagina 9 - Cutout Dimensions

Dataliner DL20 Message Display2European Union Directive Compliance If a Dataliner Message Display is installed within the European Union or EFTAregio

Pagina 10

Dataliner DL20 Message Display 3Apparatus covered by this standard is not intended for connection to a publicmains network but is intended to be conn

Pagina 11 - Connecting AC Power

Dataliner DL20 Message Display4Allow enough space within the enclosure for adequate ventilation. Consider heatproduced by other devices in the enclos

Pagina 12

Dataliner DL20 Message Display 5Installing Display in PanelTo install the Dataliner display:!ATTENTION: Disconnect all electrical power from the pane

Pagina 13 - Fuse Type

Dataliner DL20 Message Display6Mounting DimensionsFigure 1 One- and Two-Line Dimensions4.38(111.2)0.62(15.7)DIM. ”A’’SEECHART6.65(168.9)0.72(18.3)13

Pagina 14 - Additional Information

Dataliner DL20 Message Display 7Figure 2 Four-Line DL20 Dimensions0.53(13.5)0.72(18.3)2.94 (74.7)1.63(41.4)6.18(157.0)Front ViewSide View0.099 (2.5)(

Pagina 15

Dataliner DL20 Message Display8ClearancesAllow adequate clearances for mounting, air flow, maintenance, and wiring. SeeFigure 3.Figure 3 Minimum Mou

Pagina 16 - Worldwide representation

Dataliner DL20 Message Display 9Cutout DimensionsFigure 4 shows the required cut-out dimensions.Figure 4 13.62 (345.9)Cut Out6.94(176.1)5.30(134.6)Cu