Rockwell-automation 2711 MODBUS COMMUNICATIONS FOR PANELVIEW TERMINALS Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Equipo Rockwell-automation 2711 MODBUS COMMUNICATIONS FOR PANELVIEW TERMINALS. Rockwell Automation 2711 MODBUS COMMUNICATIONS FOR PANELVIEW TERMINALS User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
1 Publication 2711-6.9
User Guide
Modbus Communications
for PanelView Terminals
Introduction
This document describes how to connect and configure
communications for the Modbus versions of the PanelView terminals.
This document provides supplemental information for the
PanelBuilder32 manuals.
For more information about: Go to page:
Related Publications 2
Before using this Guide 2
Modbus Protocol 3
Modbus PanelView Terminals 3
Typical Modbus Network 4
Connector Pinout Definitions 7
Serial Port Connection 8
Modifying Modbus Settings from Terminal 9
Setting up Communications using PanelBuilder32 11
Modbus Address Spaces 14
Modbus Controller Data Table 15
Data Formats 16
Tag Editor 16
Downloading Applications over a Serial Link 19
Error Messages and Codes 20
Glossary 24
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - Introduction

1 Publication 2711-6.9 User GuideModbus Communications for PanelView TerminalsIntroductionThis document describe

Pagina 2 - Before using this guide

Publication 2711-6.9 - March 200010 Modbus Communications for PanelView Terminals Port/Modem Handshake [F5]Steps through the available op

Pagina 3 - Terminals

Publication 2711-6.9 Modbus Communications for PanelView Terminals 11Setting up Communications Setting up Modbus communications for an ap

Pagina 4 - Typical Modbus Network

Publication 2711-6.9 - March 200012 Modbus Communications for PanelView Terminals Configuring Modbus CommunicationsModbus communication p

Pagina 5 - Plus Network

Publication 2711-6.9 Modbus Communications for PanelView Terminals 133. Under Terminal, edit the following parameters:4. Click OK to exit

Pagina 6 - Connections

Publication 2711-6.9 - March 200014 Modbus Communications for PanelView Terminals Modbus Address SpacesThe PanelView reads and writes dat

Pagina 7 - Definitions

Publication 2711-6.9 Modbus Communications for PanelView Terminals 15Data and Address TypesNot all of the data types are compatible with

Pagina 8 - Making Serial Port

Publication 2711-6.9 - March 200016 Modbus Communications for PanelView Terminals Data FormatModicon controllers communicate in either AS

Pagina 9 - Modifying Modbus Settings

Publication 2711-6.9 Modbus Communications for PanelView Terminals 17Tag Editor FieldsField Description Valid Characters NotesTag Name Na

Pagina 10 - • RS-485

Publication 2711-6.9 - March 200018 Modbus Communications for PanelView Terminals Type Determines address of the data in the slave device

Pagina 11 - Setting up Communications

Publication 2711-6.9 Modbus Communications for PanelView Terminals 19Downloading Applications over a Serial LinkTo download a Modbus appl

Pagina 12

Publication 2711-6.9 - March 20002 Modbus Communications for PanelView Terminals Related publicationsThe following documentation provides

Pagina 13 - Publication 2711-6.9

Publication 2711-6.9 - March 200020 Modbus Communications for PanelView Terminals Modbus Application ReportThe application printout for M

Pagina 14 - Modbus Address Spaces

Publication 2711-6.9 Modbus Communications for PanelView Terminals 21The following errors are not specific to Modbus but may appear when

Pagina 15 - Modicon Controller Data

Publication 2711-6.9 - March 200022 Modbus Communications for PanelView Terminals Message Recommended ActionNot enough network node addre

Pagina 16 - PanelBuilder32 Tag Editor

Publication 2711-6.9 Modbus Communications for PanelView Terminals 23Communication Status Error MessagesThese errors appear as a banner a

Pagina 17 - Tag Editor Fields

Publication 2711-6.9 - March 2000 24 40061-386-01(B)Supersedes Publication 2711-6.9 - October 1997 © Copyright 2000 Rockwell International Corporatio

Pagina 18

Publication 2711-6.9 Modbus Communications for PanelView Terminals 3Modbus protocolModbus protocol links Modicon Programmable Controllers

Pagina 19 - Downloading Applications

Publication 2711-6.9 - March 20004 Modbus Communications for PanelView Terminals Typical Modbus NetworkShown below is a typical Modbus ne

Pagina 20 - Error Messages and Codes

Publication 2711-6.9 Modbus Communications for PanelView Terminals 5Connection to a Modbus Plus NetworkUsing a Bridge Multiplexer (BM85)

Pagina 21

Publication 2711-6.9 - March 20006 Modbus Communications for PanelView Terminals Making Modbus ConnectionsThe PanelView Modbus protocol c

Pagina 22

Publication 2711-6.9 Modbus Communications for PanelView Terminals 7Connector Pinout DefinitionsThe communication type is downloaded with

Pagina 23

Publication 2711-6.9 - March 20008 Modbus Communications for PanelView Terminals Making Serial Port ConnectionsUse the RS-232 serial port

Pagina 24 - Glossary

Publication 2711-6.9 Modbus Communications for PanelView Terminals 9Modifying Modbus Settings from the TerminalYou can display or modify

Comentarios a estos manuales