QUICK START
ARMORSTART
®
DISTRIBUTED
MOTOR CONTROLLER
Getting Started
BULLETIN 280D/281D
Introduction This guide provides the basic information required to start up your
ArmorStart
®
Distributed Motor Controller. Factory default settings
and information regarding installing, programming, and DeviceNet™
Node Commissioning are described here. For detailed information on
specific product features or configurations, refer to the ArmorStart
user manual, publication 280-UM001*-EN-P.
This guide is intended for qualified service personnel responsible for
setting up and servicing these devices. You must have previous
experience with and a basic understanding of electrical terminology,
configuration procedures, required equipment, and safety precautions.
You should understand DeviceNet network operations, including how
slave devices operate on a network and communicate with a
DeviceNet master. You should also be familiar with RSNetWorx™
for DeviceNet. You must use RSNetWorx for DeviceNet Revision
3.21 Service Pack 2 or later. This software package is referred to
often in this manual. Rockwell Automation product EDS files are
available on the internet at: http://www.ab.com/networks/eds
.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - MOTOR CONTROLLER

QUICK STARTARMORSTART® DISTRIBUTED MOTOR CONTROLLERGetting StartedBULLETIN 280D/281DIntroduction This guide provides the basic information required to

Pagina 2 - 2

10 Publication 280D-QS001D-EN-P - July 2006ArmorStart with ArmorConnect ConnectivityInstalling ArmorConnect Power Media using Cord GripsContro

Pagina 3 - 3

Publication 280D-QS001D-EN-P - July 2006 11ArmorConnect Cable RatingsThe ArmorConnect Power Media cables are rated per UL Type TC 600V 90 °C Dr

Pagina 4 - 4

12 Publication 280D-QS001D-EN-P - July 2006Group Motor Installations for USA and Canada MarketsThe ArmorStart Distributed Motor controllers are

Pagina 5 - 5

Publication 280D-QS001D-EN-P - July 2006 13maintenance while energized. In lieu of this service, the ArmorStart is meant to be unplugged and re

Pagina 6 - Conduit Entrance

14 Publication 280D-QS001D-EN-P - July 2006LED Status Indication The LED Status Indication provides 4 status LEDs and a Reset button. The LEDs

Pagina 7 - Disconnect Handle

Publication 280D-QS001D-EN-P - July 2006 15Node Commissioning using HardwareThe ArmorStart is shipped with the hardware rotary switches set to

Pagina 8 - Description

16 Publication 280D-QS001D-EN-P - July 2006required, the information below can be used to map a device based on the default configuration.Table

Pagina 9 - Enclosure

Publication 280D-QS001D-EN-P - July 2006 17Use the software to access the device parameters screen. By default the motor FLA is set to the mini

Pagina 10 - 10

18 Publication 280D-QS001D-EN-P - July 2006Quick Reference TroubleshootingThere are four LEDs on the front of the ArmorStart that can provide a

Pagina 11 - Three-Phase Power Media

Publication 280D-QS001D-EN-P - July 2006 19Fault LED indications for Bulletin 280D and 281D ArmorStart Distributed Motor ControllersTable 8 Con

Pagina 12 - 12

2 Publication 280D-QS001D-EN-P - July 2006Installation The ArmorStart Distributed Motor Controller is convection cooled. Operating temperature

Pagina 13 - 13

20 Publication 280D-QS001D-EN-P - July 2006Bulletin 280/281 ParametersTable 9 Starter Display and Parameter SettingsTable 10 FLA Setting Ranges

Pagina 14 - 14

Publication 280D-QS001D-EN-P - July 2006 21Figure 11 Bulletin 280/281 ArmorStartFigure 12 Bulletin 280/281 ArmorStart with ArmorConnectLED Stat

Pagina 15 - Detail A

22 Publication 280D-QS001D-EN-P - July 2006Table 11 DeviceNet Media ➊ ➊See publication M116-CA001A-EN-P for complete cable selection informatio

Pagina 16

Publication 280D-QS001D-EN-P - July 2006 23Table 12 Sensor Media ➊ ➊See Publication M116-CA001A-EN-P for complete cable selection information.➋

Pagina 17 - 17

Publication 280D-QS001D-EN-P — July 2006 41053-384-01 (1)Superecedes Publication 280D-QS001C-EN-P — September 2005 Copyright ©2006 Rockwell Automation

Pagina 18 - Troubleshooting

Publication 280D-QS001D-EN-P - July 2006 3Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Pagina 19 - Controllers

4 Publication 280D-QS001D-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Pagina 20 - Bulletin 280/281 Parameters

Publication 280D-QS001D-EN-P - July 2006 5Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Pagina 21 - 21

6 Publication 280D-QS001D-EN-P - July 2006Wiring Power, Control, Safety Monitor Inputs, and Ground Wiring Table 1 provides the power, control,

Pagina 22 - Table 11 DeviceNet Media

Publication 280D-QS001D-EN-P - July 2006 7Table 2 Power, Control, Safety Monitor, and Ground Terminal Designations➊ Only available with the Saf

Pagina 23 - Table 13 Sealing Caps

8 Publication 280D-QS001D-EN-P - July 2006ArmorConnect Power Media DescriptionThe ArmorStart Power Media offers both three-phase and control po

Pagina 24 - Trademark List

Publication 280D-QS001D-EN-P - July 2006 9Figure 7 Control Power Media System Overview➏ Control Power Media Patchcords - PatchCord cable with