Publication 4100-IN505A-EN-P - October 2000
3-8 Operation
Index Division Ratio Selection
Switch 3 and Switch 4 are used to create 4 patterns based on their
ON/OFF combinations. The patterns determine the pulse ranges, the
pulses per revolution, and the counts per revolution.
Maximum Effective Motor Speed
The Maximum Effective Motor Speed is dependent on the combined
values for Switch 3 and Switch 4. Only one of the switches numbered
5 through 10 should be in the ON position. The default setting has
Switch 5 in the ON position with switches 6 through 10 in their OFF
positions.
Table 3.D Index Division Ratio Selection
Switch Settings for
Switch 3/ Switch 4
Pulse
Range
Pulses Per
Revolution
Counts per
Revolution
OFF/OFF
2
10
1024 4096
ON/OFF
2
11
2048 8192
OFF/ON
2
12
4096 16384
ON/ON
2
13
8192 32768
TIP
Having more than one switch, in series 5 through 10,
set to the ON position results in an undefined
maximum RPM speed. No switches, in series 5
through 10, set to the ON position results in an
output speed of zero. In either case, no damage is
done to the ESRS.
Table 3.E Maximum Effective Motor Speed (RPM) Selection
Switch
Number
Switch 3 and 4 set
to: OFF/OFF
Switch 3 and 4 set
to: ON/OFF
Switch 3 and 4 set
to: OFF/ON
Switch 3 and 4 set
to: ON/ON
5 1500 750 375 187
6 3000 1500 750 375
7 6000 3000 1500 750
8 9000 4500 2250 1125
9 12000 6000 3000 1500
10 15000 7500 3750 1875