Rockwell-automation FactoryTalk Historian SE DataLink 4.2 User Guide Manual de usuario Pagina 112

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 164
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 111
FactoryTalk Historian DataLink User Guide
104
Outcodes
FactoryTalk Historian DataLink function syntax includes integer outcode
arguments. The outcodes determine how appended data (page 22) are
returned and output cells are oriented.
Outcodes are automatically generated by function dialog boxes and task
panes. However, if you enter a function manually in Excel's function bar,
you may need to calculate and include appropriate outcode values yourself.
A function outcode is a decimal representation of binary bits. In
FactoryTalk Historian DataLink, bits carry the following meanings:
1st bit: Show Timestamps bit
2nd bit: Orientation bit (columns/row)
3rd bit: Show Percent Good bit
4th bit: Hide Count bit
5th bit: Show Extended Status bit
6th bit: Show Annotations bit
7th bit: Show Start Time
8th bit: Show End Time
9th bit: Show Min/Max Time
For example, a 0 outcode in a PICurrVal() function results in a current
snapshot value in the designated output cell. An outcode of 1 places a time
stamp in column one and the snapshot value in column two of a 1 x 2
array. An outcode of 2 places a time stamp in row one and the snapshot
value in row two of a 2 x 1 array.