9 ● FactoryTalk Historian DataLink Function Reference
113
An output code to determine results placement, either 0, 1, or 2.
The target FactoryTalk Historian server.
The mode used to determine which values are retrieved.
Returns
Example:
The following retrieves the interpolated value for the tag cdep158 at
7:20pm on December 11, 1992 from the FactoryTalk Historian server
casaba:
=PIArcVal("cdep158","11-dec-92 19:20",0,
"casaba","interpolated")
PIExpVal()
Retrieves an archived FactoryTalk Historian point value based on an
expression, using the following syntax:
PIExpVal(expression, timestamp, PIServer)
Arguments
A FactoryTalk Historian calculation expression.
The time stamp corresponding to the archive value.
The target FactoryTalk Historian server.
Comentarios a estos manuales