Publication HPK-IN001C-EN-P - June 2010
Lubrication Amounts and Intervals
The tables below list the recommended amount and interval for lubrication of HPK-Series
motors.
Chevron SRI-2 or equivalent grease is recommended, unless the motor nameplate specifies a
special grease.
Catalog Number Volume Weight
HPK-B or HPK-E Cubic
Centimeter
Cubic Inches Grams Ounces
1307…1815 Lubricated for life
2010, 2212 or 2510 32 2.0 28 1.0
Service Condition Ambient
Temperature
(2)
(2) Specially designed motors are required for operation in ambient temperatures outside the range of -25…40 °C
(-13…104 °F)
Bearing Load Atmosphere Operating
Hours per Day
Standard -18…40
°C
(-0.4…104
°F)
Steady Clean 8
Severe -30…50 °C
(-22…122 °F)
Medium Shock,
Vibration
less than 0.2 in/s
Medium Dirt,
Abrasives,
Corrosion
8…24
Extreme
(1)
(1) Extreme service conditions are rare in actual practice. corresponding lubrication cycles should therefore be applied with
caution. In addition, it is advisable to check with Rockwell Automation for special instructions.
-50…65 °C
(-58…149
°F)
Heavy Shock,
Vibration
greater than 0.44
in/s
Heavy Dirt,
Abrasives,
Corrosion
8…24
Normal Operating Speed Lubrication Interval in Months
Max. rpm Standard Service Severe Service Extreme Service
3450 and higher 9 4 1
2400…3449 24 9 3
1700…2399 36 12 3
800…1399 36 24 8
500…799 48 36 12
499 and lower 48 36 12