Rockwell Automation Publication IASIMP-QS032A-EN-P - March 2012 43
Add a Kinetix 350 Drive to an RSLogix 5000 Project Chapter 2
Axis Off One of the following conditions exists:
Off
Initialization is in process - Bus not operating
Shutdown is in process - Bus not operating
Pre-charge is in process - Bus not operating
Flashing red/green Self-test (power-up diagnostics) in process
Flashing green One of the following conditions exists:
Initialization is in process- Bus is operating
Axis is stopped.
Flashing amber One of the following conditions exists:
Shutdown is in process - Bus is operating
Start is inhibited.
Steady green One of the following conditions exists:
Axis is stopping.
Axis is starting.
Axis is running.
Axis is testing.
Flashing red One of the following conditions exists:
Axis is aborting.
Axis experienced a major fault.
Steady red One of the following conditions exists:
Axis is aborting.
Axis experienced a major fault.
Table 2 - Drive Status Indicators
Status Indicator Condition Status