Pagina 1 - Serial Communications Module

User ManualBulletin 1203Serial Communications ModulePPG OPTOMUXCatalog Number 1203-GD9, –GK9

Pagina 2

Chapter 2Product Description2-2Figure 2.1Enclosed Style Serial-to-SCANport Communications ModulePowerConnectionSCANportConnectorDiagnosticLEDSRXSCANpo

Pagina 3 - Summary of Changes

Chapter 2Product Description2-3Configuration Switches The Serial Communications Module has three DIP Switches: SW1, SW2,and SW3 (Figure 2.1). Switches

Pagina 4

Chapter 2Product Description2-4This Page Intentionally Left Blank.

Pagina 5 - Table of Contents

3Chapter3-1InstallationChapter Objectives In this chapter you will learn how to: Mount the communications module Configure the communications module

Pagina 6

Chapter 3Installation3-2Factory Switch SettingsSwitch Setting Communication ModeSW1-8 OffSW1-7 OffSW1-6 OffSW1-5 OffDrive Number = 1SW1-4 OffSW1-3 Off

Pagina 7 - Introduction

Chapter 3Installation3-3Switch SW1Switch SW1 selects: Communications mode selection (RS232/RS422/RS485) Communications module addressSW1OFFON87 65 4

Pagina 8 - Safety Precautions

Chapter 3Installation3-4Table 3.BSwitch SW1 Communications Module Address SelectionPCC DriveNo.ModuleAddress(Decimal)ModuleAddress(Octal)SW1-8 SW1-7 S

Pagina 9

Chapter 3Installation3-5Switch SW2Switch SW2 selects the baud rate, parity, and speed limit.SW2OFFON8765 43 21ParitySettingBaud RateSelectionProtocol

Pagina 10 - Figure 2.1

Chapter 3Installation3-6Switch SW3Switch SW3 selects Stop Bits.SW3OFFON8765 43 21Set to OffAB0493AStop BitsTable 3.GSwitch SW3-1 – SW3-6 SettingsSW3-1

Pagina 11 - Installation

Chapter 3Installation3-7Enclosed Style Communications Module DimensionsFigure 3.1Enclosed Style Communications Module DimensionsDIN RAIL45mm(1.8)BACK

Pagina 12 - Product Description

Important User Information Because of the variety of uses for this equipment and because of thedifferences between this solid-state equipment and elec

Pagina 13

Chapter 3Installation3-8Cable ConnectionsRS485/RS422/RS232 Connection ExamplesFigure 3.2Communications Module9-Pin D-Shell123459876COMN.C.TXN.C.RXN.C.

Pagina 14 - Factory Switch Settings

Chapter 3Installation3-9SCANport Link ConnectionCable RequirementsSCANport cables are available in either male–to–male or male–to–femaleconfiguration.

Pagina 15 - Switch SW1

Chapter 3Installation3-10Power Supply Connections The enclosed communications module is powered from a separate 24V dcor 115/230V ac power supply (Fi

Pagina 16 - Table 3.B

Chapter4Chapter4-1TroubleshootingChapter Objectives Use this chapter to help troubleshoot your serial communications systemusing the LED indicators on

Pagina 17 - Table 3.F

Chapter 4Troubleshooting4-2Table 4.ALED Troubleshooting TableIndicator Color Description Recommended ActionSerial StsGreen (Blinking) Link OK, off-lin

Pagina 18 - Switch SW3

5Chapter5-1SpecificationsChapter Objectives This chapter provides background information and specifications that youmay need when installing or applyi

Pagina 19 - Module Dimensions

Chapter 5Specifications5-2This Page Intentionally Left Blank.

Pagina 20 - Cable Connections

IndexI-1IndexCCable Connections, 3-8Cable RequirementsCable length, 3-9Port Expander, 3-9SCANport, 3-9Communications ModuleCompatibility, 5-1Configura

Pagina 21 - Cable Requirements

IndexI-2This Page Intentionally Left Blank.

Pagina 23 - Troubleshooting

Summary of ChangesSummary Information Information for the –GK9 module was added to this manual.

Pagina 27

CUT ALONG DOTTED LINE ✁We Want Our Manuals to be the Best!You can help! Our manuals must meet the needs of you, the user. This is your opportunity t

Pagina 28

FOLD HEREFOLD HERENO POSTAGENECESSARYIF MAILEDIN THEUNITED STATESBUSINESS REPLY MAILPERMIT NO. 413 MEQUON, WIPOSTAGE WILL BE PAID BY ADDRESSEEALLEN-BR

Pagina 29

SCANport is a trademark of Allen-Bradley Company, Inc.

Pagina 30

Publication 1203-5.4 — April, 1996 P/N 74002-125-01(B)Supersedes July, 1995 Copyright 1994, Allen-Bradley Company, Inc. Printed in USA

Pagina 31

Summary of ChangesThis Page Intentionally Left Blank

Pagina 32

Table of ContentsiIntroduction Chapter 1Manual Objectives 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Who Shoul

Pagina 33 - CUT ALONG DOTTED LINE ✁

Table of ContentsiiThis Page Intentionally Left Blank.

Pagina 34 - ALLEN-BRADLEY

1Chapter1-1IntroductionManual Objectives The purpose of this manual is to provide you with the necessaryinformation to apply the Serial Communications

Pagina 35

Chapter 1Introduction1-2Manual Organization This manual is divided into the following chapters.Chapter Title Topics Covered1 Introduction Manual objec

Pagina 36

2Chapter2-1Product DescriptionChapter Objectives In this chapter, you will read about: Communications module features Location of configuration swit