
Chapter 3
Installation
3-9
Table 3.L
Switch SW3 Settings for Datalink D
SW3-5 Function
Off Disable Datalink D Messaging
On Enable Datalink D Messaging
Table 3.M
Switch SW3 Settings for Duplicate Message Detection
SW3-6 Duplicate Message Detection
Off Disable Duplicate Message Detection
On Enable Duplicate Message Detection
Table 3.N
Switch SW3 Settings for Application Timeout Default Value
SW3-8 SW3-7 Application Timeout Value
Off Off No Timeout (Disabled)
Off On 1 Second
On Off 30 Seconds
On On 60 Seconds
NOTE: The Application Timeout defaults to the value set by switches
SW3-7 and -8. The default value is used for Application Timeout unless
the user writes a value to the Application Timeout address in the
Communications Module Data Table. If power is removed the default value
is reloaded upon powerup.
Comentarios a estos manuales