Rockwell-automation 1336T Function Block Prog. Manual, Series A/B Manual de usuario Pagina 113

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 180
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 112
Function Block Library 4–51
1336 FORCE — 5.9 August 1995
2ADD
BLOCK TYPE 26
decimal
1A
hexadecimal
Two Input Add
ID = Exec =
Output
NODE 0
Input #1
NODE 1
Input #2
NODE 2
DEFINITION
Sums two signed numbers Input #1 and Input #2. The output Output
is clamped to ±32767 should the sum exceed these limits.
INPUT
Input #1 — A signed integer between ±32767.
Input #2 — A signed integer between ±32767.
OUTPUT
Output — A signed integer between ±32767.
FUNCTION
Output = Input #1 + Input #2.
PARAMETERS DATA TYPE LINKABLE DEFAULT VALUE RANGE
Input #1 Signed Integer Yes 0
±32767
Input #2 Signed Integer Yes 0
±32767
Output Signed Integer No
±32767
EXAMPLES EXAMPLE 1 EXAMPLE 2 EXAMPLE 3
Input #1 1 32767 32767
Input #2 2 4 –10
Output 3 32767 32767