1–6 Getting Started
1336 FORCE — 5.9 August 1995
You can now link the Set Reset Flip Flop inputs to the outputs of the
Limit function block entered in
Step 1
.
5. Link the Set Reset FF’s set input (node 0), to the maximum limit
flag of the Limit function block (node 3).
Click on the Link To field for Node 0 and enter 1:3.
Press enter to save the value as shown below.
6. Link the Set Reset FF’s reset input (node 1), to the minimum limit
flag of the Limit function block (node 4).
Click on the Link To field for Node 1 and enter 1:4.
Press enter to save the value as shown above.
With the Set Reset FF function block and links added, the function
block diagram now appears like this.
Input 1 1:0
Max Val (32765) 1:1
LIMIT
ID # 1
@ Max Lim 1:3
@ Min Lim 1:4
Output 1:5
Min Val (–32765) 1:2
Set Reset FF
ID # 2
Set 2:0
Reset 2:1
Out1 2:2
Out2 2:3